Package: Agilent_HP34970A_01A_07A_IEEE_5700A_R1.mcz
Become a MET/SUPPORT Gold Member to download this package!
Procedures in Package
Click on the procedure names to find out details about the procedure files containing them.
Agilent 34907A:(1 yr): VER/ADJ IEEE/34401A:1.00, Revision: 1
Agilent 34901A:(1 yr): VER IEEE/34401A:1.00, Revision: 1
Agilent 34970A:(1 yr): ADJ IEEE/5700A:1.00, Revision: 1
Agilent 34970A:(1 yr): VER IEEE/5700A:1.00, Revision: 1
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Agilent 34907A:(1 yr): VER/ADJ IEEE/34401A:1.00
Date: 2001-08-23
Revision: 1
Automated Reference: HP 34401A
Agilent 34901A:(1 yr): VER IEEE/34401A:1.00
Date: 2001-08-23
Revision: 1
Automated Reference: HP 34401A
Procedure ID No: 001228J003
Models covered: Module 34901A
Source: Service Guide, 34970-90011, Oct 97, Edition 2.
Source Author: Agilent
Compatibility: MET/CAL 6.10 or later
Subprocedures: nil
Required Files: nil
............
Additional equipment Required: 34970A
The Procedure was tested using:
Model Nos 34970A & 34901A
Serial Nos 02US37034294 & US37015687
Options IEEE
Firmware Rev 09-01-02
The average run time during testing was 15 minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differencesin specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Agilent 34970A:(1 yr): ADJ IEEE/5700A:1.00
Date: 2001-08-23
Revision: 1
Automated Reference: Fluke 5700A
Procedure ID No: 001228J002
Models covered: 34970A
Source: Service Guide, 34970-90011, Oct 97, Edition 2.
Source Author: Agilent
Compatibility: MET/CAL 6.10 or later
Subprocedures: nil
Required Files: 34901A.bmp
............
Additional equipment Required: 34901A Module and associated wiring
The Procedure was tested using:
Model Nos 34970A & 34901A
Serial Nos 02US37034294 & US37015687
Options IEEE
Firmware Rev 09-01-02
The average run time during testing was 20 minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differencesin specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Agilent 34970A:(1 yr): VER IEEE/5700A:1.00
Date: 2001-08-23
Revision: 1
Automated Reference: Fluke 5700A
Procedure ID No: 001228J001
Models covered: 34970A
Source: Service Guide, 34970-90011, Oct 97, Edition 2.
Source Author: Agilent
Compatibility: MET/CAL 6.10 or later
Subprocedures: Sub Average 10 Readings: 1.00
Required Files: 34901A.bmp
............
Additional equipment Required: 34901A Module and associated wiring
The Procedure was tested using:
Model Nos 34970A & 34901A
Serial Nos 02US37034294 & US37015687
Options IEEE
Firmware Rev 09-01-02
The average run time during testing was 35 minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differencesin specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Procedure ID No: 001228J004
Models covered: Module 34907A
Source: Service Guide, 34970-90011, Oct 97, Edition 2.
Source Author: Agilent
Compatibility: MET/CAL 6.10 or later
Subprocedures: nil
Required Files: 34907A
............
Additional equipment Required: 34970A
The Procedure was tested using:
Model Nos 34970A & 34907A
Serial Nos 02US37034294 & 37002735
Options IEEE
Firmware Rev 09-01-02
The average run time during testing was 5 minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differencesin specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.