Package: Tektronix_TDS_224_1_year_CAL_VER_9500.mcz
Become a MET/SUPPORT Gold Member to download this package!
Procedures in Package
Click on the procedure names to find out details about the procedure files containing them.
Tektronix TDS 224: (1 year) CAL VER / 9500-1hd: 1.00, Revision: 1
Tektronix TDS 224: (1 year) CAL VER / 9500-4hd: 1.00, Revision: 1
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Tektronix TDS 224: (1 year) CAL VER / 9500-1hd: 1.00
Date: 2001-06-26
Revision: 1
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Tektronix TDS 224: (1 year) CAL VER / 9500-4hd: 1.00
Date: 2001-06-26
Revision: 1
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Procedure ID No: 001157M001
Models covered: 210, 220, 224
Source: Tektronix TDS 200 Series
Service Manual
Digital Real-Time Oscilloscope
071-0492-02
Source Author: N/K
Compatibility: MET/CAL 6.10 or later
Subprocedures:
Sub Wait for Operation Complete (OPC) IEEE/: 1.00
Sub Tek TDS2xx: Main Trigger IEEE/: 1.00
Required Files:
Additional equipment Required:
Two BNC (f/m) Right Angle Adaptors (Pomona 90191 Model 3534)
The Procedure was tested using:
Model No TEKTRONIX TDS 224
Serial No BO25022
Options N/A
Firmware Ver FV:v1.06
Module Firmware Ver TDS2CM:CMV:v1.04
The average run time during testing was 20 minutes.
Procedure history:
21-06-01: New Procedure
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differences in specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Procedure ID No: 001157M004
Models covered: 210, 220, 224
Source: Tektronix TDS 200 Series
Service Manual
Digital Real-Time Oscilloscope
071-0492-02
Source Author: N/K
Compatibility: MET/CAL 6.10 or later
Subprocedures:
Sub Wait for Operation Complete (OPC) IEEE/: 1.00
Sub Tek TDS2xx: Main Trigger IEEE/: 1.00
Required Files:
Additional equipment Required:
The Procedure was tested using:
Model No TEKTRONIX TDS 224
Serial No BO25022
Options N/A
Firmware Ver FV:v1.06
Module Firmware Ver TDS2CM:CMV:v1.04
The average run time during testing was 20 minutes.
Procedure history:
21-06-01: New Procedure
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differences in specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.