Package: agilent_dso80x04b_1yr_ver_9500_e4418_e8257d.mcz
Become a MET/SUPPORT Gold Member to download this package!

Details about Procedure Files

Below is a list of procedure files (.pro files) in the package.

Subprocedures and procedures files that only contain subprocedures have been excluded.

The references of the subprocedure files have been included.

Agilent DSO80204B: (1 yr) VER IEEE /9500+1Hd,E8257D

Agilent DSO80304B: (1 yr) VER IEEE /9500+1Hd,E8257D

Agilent DSO80404B: (1 yr) VER IEEE /9500+1Hd,E8257D

Agilent DSO80604B: (1 yr) VER IEEE /9500+1Hd,E8257D

Date: 2006-08-03 09:47:08

Revision: 1.1

Automated Reference: Agilent E4413A

Automated Reference: Agilent E4418B

Automated Reference: Agilent E8257D

Automated Reference: Datron 9500

Automated Reference: Datron 9510

Manual Reference: Agilent 11667B

Model(s) Covered:

Agilent DSO80204B, DSO80304B, DSO80404B, DSO80604B

Compatibility:

MET/CAL 7.11 SP1 (7.11j) or later

Source(s):

Agilent 80000 Series Infiniium Oscilloscopes Service Guide,

Part No. D8104-97000, February 2006

Additional Equipment Required:

Power Splitter, 2 resistor, DC to >= 18 GHz, Agilent 11667B or

equivalent

Adapter, 3.5 mm (f) SMA to Precision BNC, Agilent Part No.

54855-67604, No Substitute

Adapter, 3.5 mm (m) to 3.5 mm (m) SMA, Agilent Part No. E2655-83202

or equivalent

Coaxial cable, 3.5 mm (m) to 3.5 mm (m) SMA, DC to >= 18 GHz,

Agilent Part No. 8120-4948 or equivalent

Average run time during testing:

34 min. (TAR mode), 2 hr. 9 min. (MU mode)

Agilent DSO80204B: (1 yr) VER IEEE /9500+4Hd,E8257D

Agilent DSO80304B: (1 yr) VER IEEE /9500+4Hd,E8257D

Agilent DSO80404B: (1 yr) VER IEEE /9500+4Hd,E8257D

Agilent DSO80604B: (1 yr) VER IEEE /9500+4Hd,E8257D

Date: 2006-08-03 09:47:11

Revision: 1.1

Automated Reference: Agilent E4413A

Automated Reference: Agilent E4418B

Automated Reference: Agilent E8257D

Automated Reference: Datron 9500

Automated Reference: Datron 9510

Manual Reference: Agilent 11667B

Model(s) Covered:

Agilent DSO80204B, DSO80304B, DSO80404B, DSO80604B

Compatibility:

MET/CAL 7.11 SP1 (7.11j) or later

Source(s):

Agilent 80000 Series Infiniium Oscilloscopes Service Guide,

Part No. D8104-97000, February 2006

Additional Equipment Required:

Power Splitter, 2 resistor, DC to >= 18 GHz, Agilent 11667B or

equivalent

Adapter, 3.5 mm (f) SMA to Precision BNC, Agilent Part No.

54855-67604, No Substitute

Adapter, 3.5 mm (m) to 3.5 mm (m) SMA, Agilent Part No. E2655-83202

or equivalent

Coaxial cable, 3.5 mm (m) to 3.5 mm (m) SMA, DC to >= 18 GHz,

Agilent Part No. 8120-4948 or equivalent

Average run time during testing:

34 min. (TAR mode), 2 hr. 9 min. (MU mode)