Package: agilent_dso8xx04ab_1yr_ver_9500_e4418_e8257d.mcz
Become a MET/SUPPORT Gold Member to download this package!
Procedures in Package
Click on the procedure names to find out details about the procedure files containing them.
Agilent DSO80804A: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO81004A: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO81204A: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO81304A: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO80804A: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO81004A: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO81204A: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO81304A: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO80804B: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO81004B: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO81204B: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO81304B: (1 yr) VER IEEE /9500+1Hd,E8257D, Revision: 1.1
Agilent DSO80804B: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO81004B: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO81204B: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Agilent DSO81304B: (1 yr) VER IEEE /9500+4Hd,E8257D, Revision: 1.1
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Agilent DSO80804A: (1 yr) VER IEEE /9500+1Hd,E8257D
Agilent DSO81004A: (1 yr) VER IEEE /9500+1Hd,E8257D
Agilent DSO81204A: (1 yr) VER IEEE /9500+1Hd,E8257D
Agilent DSO81304A: (1 yr) VER IEEE /9500+1Hd,E8257D
Date: 2006-08-03 09:51:15
Revision: 1.1
Automated Reference: Agilent E4413A
Automated Reference: Agilent E4418B
Automated Reference: Agilent E8257D
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Manual Reference: Agilent 11667B
Agilent DSO80804A: (1 yr) VER IEEE /9500+4Hd,E8257D
Agilent DSO81004A: (1 yr) VER IEEE /9500+4Hd,E8257D
Agilent DSO81204A: (1 yr) VER IEEE /9500+4Hd,E8257D
Agilent DSO81304A: (1 yr) VER IEEE /9500+4Hd,E8257D
Date: 2006-08-03 09:51:18
Revision: 1.1
Automated Reference: Agilent E4413A
Automated Reference: Agilent E4418B
Automated Reference: Agilent E8257D
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Manual Reference: Agilent 11667B
Model(s) Covered:
Agilent DSO80804A, DSO81004A, DSO81204A, DSO81304A
Compatibility:
MET/CAL 7.11 SP1 (7.11j) or later
Source(s):
Agilent Model 80000 Series Infiniium Oscilloscopes Service Guide,
Part No. 54856-97001, May 2005
Additional Equipment Required:
Power Splitter, 2 resistor, DC to >= 18 GHz, Agilent 11667B or
equivalent
Adapter, 3.5 mm (f) SMA to Precision BNC, Agilent Part No.
54855-67604, No Substitute
Adapter, 3.5 mm (m) to 3.5 mm (m) SMA, Agilent Part No. E2655-83202
or equivalent
Coaxial cable, 3.5 mm (m) to 3.5 mm (m) SMA, DC to >= 18 GHz,
Agilent Part No. 8120-4948 or equivalent
Average run time during testing:
34 min. (TAR mode), 2 hr. 9 min. (MU mode)
Agilent DSO80804B: (1 yr) VER IEEE /9500+1Hd,E8257D
Agilent DSO81004B: (1 yr) VER IEEE /9500+1Hd,E8257D
Agilent DSO81204B: (1 yr) VER IEEE /9500+1Hd,E8257D
Agilent DSO81304B: (1 yr) VER IEEE /9500+1Hd,E8257D
Date: 2006-08-03 09:51:21
Revision: 1.1
Automated Reference: Agilent E4413A
Automated Reference: Agilent E4418B
Automated Reference: Agilent E8257D
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Manual Reference: Agilent 11667B
Model(s) Covered:
Agilent DSO80804B, DSO81004B, DSO81204B, DSO81304B
Compatibility:
MET/CAL 7.11 SP1 (7.11j) or later
Source(s):
Agilent 80000 Series Infiniium Oscilloscopes Service Guide,
Part No. D8104-97000, February 2006
Additional Equipment Required:
Power Splitter, 2 resistor, DC to >= 18 GHz, Agilent 11667B or
equivalent
Adapter, 3.5 mm (f) SMA to Precision BNC, Agilent Part No.
54855-67604, No Substitute
Adapter, 3.5 mm (m) to 3.5 mm (m) SMA, Agilent Part No. E2655-83202
or equivalent
Coaxial cable, 3.5 mm (m) to 3.5 mm (m) SMA, DC to >= 18 GHz,
Agilent Part No. 8120-4948 or equivalent
Average run time during testing:
34 min. (TAR mode), 2 hr. 9 min. (MU mode)
Agilent DSO80804B: (1 yr) VER IEEE /9500+4Hd,E8257D
Agilent DSO81004B: (1 yr) VER IEEE /9500+4Hd,E8257D
Agilent DSO81204B: (1 yr) VER IEEE /9500+4Hd,E8257D
Agilent DSO81304B: (1 yr) VER IEEE /9500+4Hd,E8257D
Date: 2006-08-03 09:51:25
Revision: 1.1
Automated Reference: Agilent E4413A
Automated Reference: Agilent E4418B
Automated Reference: Agilent E8257D
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Manual Reference: Agilent 11667B
Model(s) Covered:
Agilent DSO80804B, DSO81004B, DSO81204B, DSO81304B
Compatibility:
MET/CAL 7.11 SP1 (7.11j) or later
Source(s):
Agilent 80000 Series Infiniium Oscilloscopes Service Guide,
Part No. D8104-97000, February 2006
Additional Equipment Required:
Power Splitter, 2 resistor, DC to >= 18 GHz, Agilent 11667B or
equivalent
Adapter, 3.5 mm (f) SMA to Precision BNC, Agilent Part No.
54855-67604, No Substitute
Adapter, 3.5 mm (m) to 3.5 mm (m) SMA, Agilent Part No. E2655-83202
or equivalent
Coaxial cable, 3.5 mm (m) to 3.5 mm (m) SMA, DC to >= 18 GHz,
Agilent Part No. 8120-4948 or equivalent
Average run time during testing:
34 min. (TAR mode), 2 hr. 9 min. (MU mode)
Model(s) Covered:
Agilent DSO80804A, DSO81004A, DSO81204A, DSO81304A
Compatibility:
MET/CAL 7.11 SP1 (7.11j) or later
Source(s):
Agilent Model 80000 Series Infiniium Oscilloscopes Service Guide,
Part No. 54856-97001, May 2005
Additional Equipment Required:
Power Splitter, 2 resistor, DC to >= 18 GHz, Agilent 11667B or
equivalent
Adapter, 3.5 mm (f) SMA to Precision BNC, Agilent Part No.
54855-67604, No Substitute
Adapter, 3.5 mm (m) to 3.5 mm (m) SMA, Agilent Part No. E2655-83202
or equivalent
Coaxial cable, 3.5 mm (m) to 3.5 mm (m) SMA, DC to >= 18 GHz,
Agilent Part No. 8120-4948 or equivalent
Average run time during testing: