Datron 1061A: (90 Day) CAL VER IEEE /5700, Revision: 1.2
Datron 1061A: (1 Year) CAL VER IEEE /5700, Revision: 1.2
Datron 1061A: CAL ADJ IEEE /5700, Revision: 1.2
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Datron 1061A: (90 Day) CAL VER IEEE /5700
Date: 2002-12-06
Revision: 1.2
Automated Reference: Fluke 5700A
Datron 1061A: (1 Year) CAL VER IEEE /5700
Date: 2002-12-06
Revision: 1.2
Automated Reference: Fluke 5700A
Models covered: 1061A
Source: Users Handbook
Part Number 850040
Issue 11 (OCT.1986)
Portocal II
Verify to 365 day
Datron 1061A
Version 1.10
Pre Adjustment Procedure
Compatibility: MET/CAL 6.11A or later
Subprocedures: Sub Wait
Sub Datron 10xx Take Reading IEEE
Sub Datron 10xx Input Zero IEEE
Required Files: 1081back - Power Lead and IEEE Connection Bitmap
1081_dis - Cal key set to RUN Bitmap
1081in57 - Connections Bitmap
Additional equipment Required:
The Procedure was tested using:
Model No 1061A
Serial No 14262
Options 10 20 30 40 50
The average run time during testing was 55 minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differences in specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Registers Used
M[1]= Average Readings Counter (Adjustment)
M[2]= Readings to Discard (Adjustment)
M[3]= Sum of Averages (Adjustment)
M[4]= Average of Readings (Adjustment)
M[6]= First Delimited Value to Identify Option 12
M[7]= Second Delimited Value to Identify Option 12
M[10]= Number of Readings Reqd (Adjustment)
M[255]= Delay Time Total
M[101]= Adjustment Retry Counter
M[102]= Invalid Measurement Counter
M[103]= Units Multiplier
M[104]= Tolerance
M[105]= Tight Tolerance % Multiplier
M[106]= Delay Time Remain Counter
M[107]= Tight Limit Calculated
S[32] = Delay Time Message
S[2] = Range String
S[10]= DCV Function Selected
S[11]= ACV Function Selectied
S[12]= Resistance Function Selected
S[13]= DCI Function Selected
S[14]= ACI Function Selected
S[20]= DCV Function Option Fitted
S[21]= ACV Function Option Fitted
S[22]= Resistance Function Option Fitted
S[23]= DCI Function Option Fitted
S[24]= ACI Function Option Fitted
S[25]= Message to explain that Option 12 is not supported.
Datron 1061A: CAL ADJ IEEE /5700
Date: 2002-12-06
Revision: 1.2
Automated Reference: Fluke 5700A
Models covered: 1061A
Source: Calibration & Servicing Handbook
Part Number 850045
Issue 9 (SEPT.1988)
Portocal II
Adjustment
Datron 1061A
Version 1.10
Full Adjustment Procedure
Compatibility: MET/CAL 6.11A or later
Subprocedures: Sub Wait
Sub Datron 10xx Take Reading IEEE
Sub Datron 10xx Cal Adjust IEEE
Required Files: 1081back - Power Lead and IEEE Connection Bitmap
1081_dis - Cal key set to RUN Bitmap
1081in57 - Connections Bitmap
Additional equipment Required:
1 MOhm Lin Source (Datron Number 400391)
10 MOhm Ib Source (Datron Number 400392)
1 Short Link
The Procedure was tested using:
Model No 1061A
Serial No 14262
Options 10 20 30 40 50
The average run time during testing was minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differences in specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Registers Used
M[1]= Average Readings Counter (Adjustment)
M[2]= Readings to Discard (Adjustment)
M[3]= Sum of Averages (Adjustment)
M[4]= Average of Readings (Adjustment)
M[6]= First Delimited Value to Identify Option 12
M[7]= Second Delimited Value to Identify Option 12
M[10]= Number of Readings Reqd (Adjustment)
M[255]= Delay Time Total
M[101]= Adjustment Retry Counter
M[102]= Invalid Measurement Counter
M[103]= Units Multiplier
M[104]= Tolerance
M[105]= Tight Tolerance % Multiplier
M[106]= Delay Time Remain Counter
M[107]= Tight Limit Calculated
S[32] = Delay Time Message
S[2] = Range String
S[10]= DCV Function Selected
S[11]= ACV Function Selectied
S[12]= Resistance Function Selected
S[13]= DCI Function Selected
S[14]= ACI Function Selected
S[20]= DCV Function Option Fitted
S[21]= ACV Function Option Fitted
S[22]= Resistance Function Option Fitted
S[23]= DCI Function Option Fitted
S[24]= ACI Function Option Fitted
S[25]= Message to explain that Option 12 is not supported.
Models covered: 1061A
Source: Users Handbook
Part Number 850040
Issue 11 (OCT.1986)
Portocal II
Verify to 90 day
Datron 1061A
Version 1.10
Pre Adjustment Procedure
Compatibility: MET/CAL 6.11A or later
Subprocedures: Sub Wait
Sub Datron 10xx Take Reading IEEE
Sub Datron 10xx Input Zero IEEE
Required Files: 1081back - Power Lead and IEEE Connection Bitmap
1081_dis - Cal key set to RUN Bitmap
1081in57 - Connections Bitmap
Additional equipment Required:
The Procedure was tested using:
Model No 1061A
Serial No 14262
Options 10 20 30 40 50
The average run time during testing was 55 minutes.
The procedure is intended for use with Met/Cal(r) calibration software,
and the terms and conditions set forth in your METCAL license apply to
this procedure.
Due to our policy of continuously up dating our products, this procedure
may contain minor differences in specification to those found in the manual
or other documentation. While every effort has been made to ensure that
this procedure is accurate, Fluke cannot be held responsible for the
consequences of error or omissions found within this procedure.
The copyright in this procedure is owned by Fluke Precision Measurement
Limited.
Registers Used
M[1]= Average Readings Counter (Adjustment)
M[2]= Readings to Discard (Adjustment)
M[3]= Sum of Averages (Adjustment)
M[4]= Average of Readings (Adjustment)
M[6]= First Delimited Value to Identify Option 12
M[7]= Second Delimited Value to Identify Option 12
M[10]= Number of Readings Reqd (Adjustment)
M[255]= Delay Time Total
M[101]= Adjustment Retry Counter
M[102]= Invalid Measurement Counter
M[103]= Units Multiplier
M[104]= Tolerance
M[105]= Tight Tolerance % Multiplier
M[106]= Delay Time Remain Counter
M[107]= Tight Limit Calculated
S[32] = Delay Time Message
S[2] = Range String
S[10]= DCV Function Selected
S[11]= ACV Function Selectied
S[12]= Resistance Function Selected
S[13]= DCI Function Selected
S[14]= ACI Function Selected
S[20]= DCV Function Option Fitted
S[21]= ACV Function Option Fitted
S[22]= Resistance Function Option Fitted
S[23]= DCI Function Option Fitted
S[24]= ACI Function Option Fitted
S[25]= Message to explain that Option 12 is not supported.