Package: fluke_165xb_1yr_ver_rs232_5320_vlc_ResBox.mcz
Become a MET/SUPPORT Gold Member to download this package!
Procedures in Package
Click on the procedure names to find out details about the procedure files containing them.
Fluke 1651B: (1 year) CAL VER RS-232 /5320+VLC,ResBox, Revision: 1.10
Fluke 1652B: (1 year) CAL VER RS-232 /5320+VLC,ResBox, Revision: 1.10
Fluke 1653B: (1 year) CAL VER RS-232 /5320+VLC,ResBox, Revision: 1.10
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Fluke 1651B: (1 year) CAL VER RS-232 /5320+VLC,ResBox
Fluke 1652B: (1 year) CAL VER RS-232 /5320+VLC,ResBox
Fluke 1653B: (1 year) CAL VER RS-232 /5320+VLC,ResBox
Date: 2009-05-01 10:21:16
Revision: 1.10
Automated Reference: Fluke 5320A
Manual Reference: Decade "R" Box
Model Covered: 1651B, 1652B, 1653B
This procedure contains the following tests whose Test Uncertainty Ratio
are less than 4:1.
Insulation
- 18 MOhm, 250 V; TUR 3.3333
- 180 MOhm, 250 V; TUR 3.3333
- 18 MOhm, 500 V; TUR 3.3333
- 180 MOhm, 500 V; TUR 3.3333
- 180 MOhm, 1000 V; TUR 2.0833
Continuity
- 2 Ohm; TUR 3.7500
Loop
- 50 Ohm; Comp; TUR 3.3333
- 180 Ohm; Comp; TUR 3.6000
Source: Fluke 1651B, 1652B, 1653B
Electrical Installation Tester
Product Specifications
Preliminary Calibration Information, July 2008
Source Author: Fluke
Compatibility: 5500/CAL or MET/CAL 7.20C or later
Additional Equipment Required:
Decade Resistor Box
Resistance: 18, 180, & 1800 Ohms
Accuracy: 0.75 % or better
Power: 0.5 W minimum
Fluke IR Adapter-Serial Cable, Part No. 2043365
Fluke-165xB, Zero Adapter, Part No. 3301338