Fluke 333: (1 year) CAL VER /5520,5500A/COIL, Revision: 1.3
Fluke 334: (1 year) CAL VER /5520,5500A/COIL, Revision: 1.1
Fluke 335: (1 year) CAL VER /5520,5500A/COIL, Revision: 1.1
Fluke 336: (1 year) CAL VER /5520,5500A/COIL, Revision: 1.2
Fluke 337: (1 year) CAL VER /5520,5500A/COIL, Revision: 1.2
Fluke 333: CAL ADJ /5520,5500A/COIL, Revision: 1.1
Fluke 334: CAL ADJ /5520,5500A/COIL, Revision: 1.1
Fluke 335: CAL ADJ /5520,5500A/COIL, Revision: 1.1
Fluke 336: CAL ADJ /5520,5500A/COIL, Revision: 1.1
Fluke 337: CAL ADJ /5520,5500A/COIL, Revision: 1.1
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Fluke 333: (1 year) CAL VER /5520,5500A/COIL
Date: 2009-09-29 09:31:37
Revision: 1.3
Automated Reference: Fluke 5500A-COIL
Automated Reference: Fluke 5520A
Fluke 334: (1 year) CAL VER /5520,5500A/COIL
Fluke 335: (1 year) CAL VER /5520,5500A/COIL
Date: 2009-09-29 09:31:38
Revision: 1.1
Automated Reference: Fluke 5500A-COIL
Automated Reference: Fluke 5520A
Model(s) Covered:
334, 335
This procedure contains the following test(s) whose Test Uncertainty Ratio
are less than 4:1.
20 A, 50 Hz; TUR 2.4845
200 A, 50 Hz; TUR 2.1971
600 A, 50 Hz; TUR 2.8808
Source:
Fluke 33X Calibration Manual, Part No. 1618765, June 2001.
Fluke 33x Calibration Maunal Supplement. Part No.1618765, June 2001
Source Author:
Fluke
Compatibility:
MET/CAL or 5500/CAL 7.20x or later
Additional Equipment Required:
None
The average run time during testing was 6 minutes or less.
Fluke 336: (1 year) CAL VER /5520,5500A/COIL
Fluke 337: (1 year) CAL VER /5520,5500A/COIL
Date: 2009-09-29 09:31:41
Revision: 1.2
Automated Reference: Fluke 5500A-COIL
Automated Reference: Fluke 5520A
Model(s) Covered:
336, 337
This procedure contains the following test(s) whose Test Uncertainty Ratio
are less than 4:1.
20 A, 50 Hz; TUR 2.4845
200 A, 50 Hz; TUR 2.1971
20 A; TUR 3.7488
-20 A; TUR 3.7488
600 A; TUR 3.5139
-600 A; TUR 3.5139
Fluke 337 only.
900 A, 50 Hz; TUR 3.0543
900 A; TUR 3.6367
-900 A; TUR 3.6367
Source:
Fluke 33X Calibration Manual, Part No. 1618765, June 2001.
Fluke 33x Calibration Maunal Supplement. Part No.1618765, June 2001
Source Author:
Fluke
Compatibility:
MET/CAL or 5500/CAL 7.20x or later
Additional Equipment Required:
None
The average run time during testing was 6 minutes or less.
Fluke 333: CAL ADJ /5520,5500A/COIL
Fluke 334: CAL ADJ /5520,5500A/COIL
Fluke 335: CAL ADJ /5520,5500A/COIL
Date: 2009-09-29 09:31:47
Revision: 1.1
Automated Reference: Fluke 5500A-COIL
Automated Reference: Fluke 5520A
Model(s) Covered:
333, 334, 335
Source:
Fluke 33X Calibration Manual, Part No. 1618765, June 2001.
Source Author:
Fluke
Compatibility:
MET/CAL or 5500/CAL 7.20x or later
Additional Equipment Required:
DC power supplier: 3 V
The average run time during testing was 6 minutes or less.
Fluke 336: CAL ADJ /5520,5500A/COIL
Fluke 337: CAL ADJ /5520,5500A/COIL
Date: 2009-09-29 09:31:52
Revision: 1.1
Automated Reference: Fluke 5500A-COIL
Automated Reference: Fluke 5520A
Model(s) Covered:
336, 337
Source:
Fluke 33X Calibration Manual, Part No. 1618765, June 2001.
Source Author:
Fluke
Compatibility:
MET/CAL or 5500/CAL 7.20x or later
Additional Equipment Required:
DC power supplier: 3 V
The average run time during testing was 6 minutes or less.
Model(s) Covered:
333
This procedure contains the following test(s) whose Test Uncertainty Ratio
are less than 4:1.
20 A, 50 Hz; TUR 2.4845
400 A, 50 Hz; TUR 2.1971
600 A, 50 Hz; TUR 2.6616
Source:
Fluke 33X Calibration Manual, Part No. 1618765, June 2001.
Fluke 33x Calibration Maunal Supplement. Part No.1618765, June 2001
Source Author:
Fluke
Compatibility:
MET/CAL or 5500/CAL 7.20x or later
Additional Equipment Required:
None
The average run time during testing was 6 minutes or less.