Fluke 51 II: (1 year) CAL VER /5520, Revision: 1.11
Fluke 52 II: (1 year) CAL VER /5520, Revision: 1.11
Fluke 53 II: (1 year) CAL VER /5520, Revision: 1.11
Fluke 54 II: (1 year) CAL VER /5520, Revision: 1.11
Fluke 51 II: CAL ADJ /5520, Revision: 1.6
Fluke 52 II: CAL ADJ /5520, Revision: 1.6
Fluke 53 II: CAL ADJ /5520, Revision: 1.6
Fluke 54 II: CAL ADJ /5520, Revision: 1.6
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Fluke 51 II: (1 year) CAL VER /5520
Fluke 52 II: (1 year) CAL VER /5520
Fluke 53 II: (1 year) CAL VER /5520
Fluke 54 II: (1 year) CAL VER /5520
Date: 2009-07-28 14:03:16
Revision: 1.11
Automated Reference: Fluke 5520A
Date: 2009-07-28 14:03:19
Revision: 1.6
Automated Reference: Fluke 5520A
Model(s) Covered: 51, 52, 53, & 54 Series II
Source: 51, 52, 53, 54, Series II Thermometer Service Manual
PN 1276123 October 1999
Source Author: Fluke
Compatibility: 5500/CAL or MET/CAL 7.20 SP1 (7.20x) or later
Subprocedures: Sub MET/CAL Version Check
Sub Display Copyright
Required Files: None
Additional Equipment Required:
Type K SMP plug to SMP plug thermocouple cable
Copper SMP plug to SMP plug cable
Model(s) Covered:
51, 52, 53, & 54 Series II
This procedure contains tests whose Test Uncertainty Ratios are less
than 4:1, based on 5520A (90 day) specifications.
0 °C; TUR 2.5000
23 °C; TUR 2.5958
-190 °C; TUR 2.7200
1200 °C; TUR 3.3333
Source:
51, 52, 53, 54, Series II Thermometer Service Manual
PN 1276123 October 1999
Source Author:
Fluke
Compatibility:
5500/CAL or MET/CAL 7.20 SP1 (7.20x) or later
Subprocedures:
Sub MET/CAL Version Check
Sub Display Copyright
Sub Select Failed Test Mode
Sub Select Guardbanding & Ver Method (No NTHROW)
Sub Fluke 50 Series II Display & Keypad Tests
Sub Fluke 50 Series II (1 yr) Temperature CAL VER /5520
Sub Fluke 53,54 II IR Communication Port Test
Required Files:
51ii_dsp.jpg Fluke 51 II display test
52ii_dsp.jpg Fluke 52 II display test
53ii_dsp.jpg Fluke 53 II display test
54ii_dsp.jpg Fluke 54 II display test
Additional Equipment Required:
Type K SMP plug to SMP plug thermocouple cable (1)
IR Interface Adapter, Fluke 53,54 only (2)
IR Cable Adapter Connector, Fluke 53,54 only (2)
DB9 (f) to DB9 (f) null modem and DB9 (m) to
DB9 (m) gender changer (only needed if UUT is connected
to 5520A UUT Serial Port) (2)
1. Included in 5500A/LEADS, Lead Set
2. Only necessary if IR Communication Port is tested.
Included in MET/CAL-SERIAL, Closed Loop Procedure
Serial Connectivity Kit.