Fluke 724: (1 year) CAL VER RS-232 /5500,8508

Date: 2009-06-19 11:33:15

Revision: 1.5

Automated Reference: Fluke 5500A

Automated Reference: Fluke 8508A

Model(s) Covered: 724

This procedure contains the following tests whose Test Uncertainty Ratio

are less than 4:1. In order to improve this, we use 8508A to characterize

the 5500A in advance for some specified test points whose TUR is lower than

3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).

mA Measurement Lower and Upper

- Range 24 mA: 12 mA ; TUR1 3.0345; TUR2 18.333

- Range 24 mA: 24 mA ; TUR1 2.5660; TUR2 8.1339

Source: Fluke 724/725 Calibrators

Calibration Manual

PN 667581, September 1999 Rev.2, 2/06

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

FLUKE-700SC Serial Interface Cable Assembly (1)

DB9 null modem adapter (1)(3)

DB9 gender changer (1)(3)

2 ea. dual banana to separated single banana shielded

cable. POMONA 1368 A-30 or equivalent

Type K SMP plug to SMP plug thermocouple cable (2)

1. Included in MET/CAL-SERIAL, Closed Loop Procedure

Serial Connectivity Kit.

2. Included in 5500A/LEADS, Lead Set

3. Only needed if UUT is connected to 5500 UUT Serial

Port.

Fluke 725: (1 year) CAL VER RS-232 /5500,8508

Date: 2009-06-19 11:33:18

Revision: 1.5

Automated Reference: Fluke 5500A

Automated Reference: Fluke 8508A

Model(s) Covered: 725

This procedure contains the following tests whose Test Uncertainty Ratio

are less than 4:1. In order to improve this, we use 8508A to characterize

the 5500A in advance for some specified test points whose TUR is lower than

3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).

mA Measurement Lower and Upper

- Range 24 mA: 12 mA ; TUR1 3.0345; TUR2 18.333

- Range 24 mA: 24 mA ; TUR1 2.5660; TUR2 3.9788

MILLIAMPS SOURCE: Lower Display

- Range 24 mA; 24 mA ; TUR 3.8549

Source: Fluke 724/725 Calibrators

Calibration Manual

PN 667581, September 1999 Rev.2, 2/06

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

FLUKE-700SC Serial Interface Cable Assembly (1)

DB9 null modem adapter (1)(3)

DB9 gender changer (1)(3)

2 ea. dual banana to separated single banana shielded

cable. POMONA 1368 A-30 or equivalent

Type K SMP plug to SMP plug thermocouple cable (2)

1. Included in MET/CAL-SERIAL, Closed Loop Procedure

Serial Connectivity Kit.

2. Included in 5500A/LEADS, Lead Set

3. Only needed if UUT is connected to 5500 UUT Serial

Port.

Fluke 725Ex: (1 year) CAL VER RS-232 /5500,8508

Date: 2009-06-19 11:33:21

Revision: 1.1

Automated Reference: Fluke 5500A

Automated Reference: Fluke 8508A

Model(s) Covered: 725Ex

This procedure contains the following tests whose Test Uncertainty Ratio

are less than 4:1. In order to improve this, we use 8508A to characterize

the 5500A in advance for some specified test points whose TUR is lower than

3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).

mA Measurement Lower and Upper

- Range 24 mA: 12 mA; TUR1 3.0345; TUR2 18.333

- Range 24 mA: 24 mA; TUR1 2.5660; TUR2 3.9799

FOUR-WIRE RESISTANCE MEASUREMENT: Lower Display

- 300.00Z; TUR 2.3810

- 1500.0Z; TUR 2.5641

- 3000.0Z; TUR 3.0303

Four-Wire RTD: Lower Display

- 550.0 degC; TUR 3.0000

TC Measure: Lower Display

- -180.0 degC: TUR 3.7037

TC Source: Lower Display

- -180.0 degC: TUR 3.7037

MILLIAMPS SOURCE: Lower Display

- Range 24 mA: 20 mA; TUR 2.3810

- Range 24 mA: 24 mA; TUR 3.8549

Source: Fluke 725Ex Multifunction Process Calibrator

Calibration Manual

PN 2406553, January 2005 Rev. 1,5/09

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

- FLUKE-700SC Serial Interface Cable Assembly

- Fluke 724/725 Calibration Cable, Part No. 1556747

- DB9(f) to DB9(m) null modem and DB9(m) to DB9(m)

gender changer. (Only needed if UUT is connected to

55xx UUT Serial Port.

- Type J SMP plug to SMP plug thermocouple cable

Included in 5500A/LEADS, Lead Set

- MET/CAL-SERIAL, Closed Loop Procedure Serial

Connectivity Kit.

Fluke 724 (Rev >= 1.04): CAL ADJ RS-232 /5500,8508

Date: 2009-06-19 11:33:24

Revision: 1.6

Automated Reference: Fluke 5500A

Automated Reference: Fluke 8508A

Model(s) Covered: 724 with firmware revision 1.04 or later

Source: Fluke 724/725 Calibrators

Calibration Manual

PN 667581, September 1999 Rev.2, 2/06

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

FLUKE-700SC Serial Interface Cable Assembly (1), DB9(f) to DB9(f)

null modem and DB9(m) to DB9(m) gender changer (only required if

UUT is connected to 5500 UUT Serial Port) (1)

2 ea., dual banana to separated single banana shielded cable,

Pomona Model 1368 A-30 or equivalent

Type K SMP plug to SMP plug thermocouple cable (2)

1. Included in MET/CAL-SERIAL, Closed Loop Procedure

Serial Connectivity Kit.

2. Included in 5500A/LEADS, Lead Set

Fluke 725: CAL ADJ RS-232 /5500,8508

Date: 2009-06-19 11:33:27

Revision: 1.5

Automated Reference: Fluke 5500A

Automated Reference: Fluke 8508A

Model(s) Covered: 725

Source: Fluke 724/725 Calibrators

Calibration Manual

PN 667581, September 1999 Rev.2, 2/06

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

FLUKE-700SC Serial Interface Cable Assembly (1), DB9(f) to DB9(f)

null modem and DB9(m) to DB9(m) gender changer (only required if

UUT is connected to 5500 UUT Serial Port) (1)

2 ea., dual banana to separated single banana shielded cable,

Pomona Model 1368 A-30 or equivalent

Type K SMP plug to SMP plug thermocouple cable (2)

1. Included in MET/CAL-SERIAL, Closed Loop Procedure

Serial Connectivity Kit.

2. Included in 5500A/LEADS, Lead Set

Fluke 725Ex: CAL ADJ RS-232 /5500,8508

Date: 2009-06-19 11:33:30

Revision: 1.1

Automated Reference: Fluke 5500A

Automated Reference: Fluke 8508A

Model(s) Covered: 725Ex

Source: Fluke 725Ex Multifunction Process Calibrator

Calibration Manual

PN 2406553, January 2005 Rev. 1,5/09

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

- FLUKE-700SC Serial Interface Cable Assembly

- Fluke 724/725 Calibration Cable, Part No. 1556747

- DB9(f) to DB9(m) null modem and DB9(m) to DB9(m)

gender changer. (Only needed if UUT is connected to

55xx UUT Serial Port.

- Type J SMP plug to SMP plug thermocouple cable

Included in 5500A/LEADS, Lead Set

- MET/CAL-SERIAL, Closed Loop Procedure Serial

Connectivity Kit.