Package: fluke_724_725_725Ex_cal_rs232_5520_3458.mcz
Become a MET/SUPPORT Gold Member to download this package!
Procedures in Package
Click on the procedure names to find out details about the procedure files containing them.
Fluke 724: (1 year) CAL VER RS-232 /5520,3458, Revision: 1.26
Fluke 725: (1 year) CAL VER RS-232 /5520,3458, Revision: 1.26
Fluke 725Ex: (1 year) CAL VER RS-232 /5520,3458, Revision: 1.1
Fluke 724 (Rev >= 1.04): CAL ADJ RS-232 /5520,3458, Revision: 1.21
Fluke 725: CAL ADJ RS-232 /5520,3458, Revision: 1.20
Fluke 725Ex: CAL ADJ RS-232 /5520,3458, Revision: 1.1
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Fluke 724: (1 year) CAL VER RS-232 /5520,3458
Date: 2009-06-19 11:47:49
Revision: 1.26
Automated Reference: Fluke 5520A
Automated Reference: HP 3458A
Fluke 725: (1 year) CAL VER RS-232 /5520,3458
Date: 2009-06-19 11:47:52
Revision: 1.26
Automated Reference: Fluke 5520A
Automated Reference: HP 3458A
Model(s) Covered: 725
This procedure contains the following tests whose Test Uncertainty Ratio
are less than 4:1. In order to improve this, we use 3458A to characterize
the 5520A in advance for some specified test points whose TUR is lower than
3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).
mA Measurement Lower and Upper
- Range 24 mA: 12 mA ; TUR1 3.0345; TUR2 18.333
- Range 24 mA: 24 mA ; TUR1 2.5660; TUR2 8.1339
Source: Fluke 724/725 Calibrators
Calibration Manual
PN 667581, September 1999 Rev.2, 2/06
Compatibility: MET/CAL 7.20 SP1 (7.20x) or later
Additional Equipment Required:
FLUKE-700SC Serial Interface Cable Assembly (1)
DB9 null modem adapter (1)(3)
DB9 gender changer (1)(3)
2 ea. dual banana to separated single banana shielded
cable. POMONA 1368 A-30 or equivalent
Type K SMP plug to SMP plug thermocouple cable (2)
1. Included in MET/CAL-SERIAL, Closed Loop Procedure
Serial Connectivity Kit.
2. Included in 5500A/LEADS, Lead Set
3. Only needed if UUT is connected to 5520 UUT Serial
Port.
Fluke 725Ex: (1 year) CAL VER RS-232 /5520,3458
Date: 2009-06-19 11:47:55
Revision: 1.1
Automated Reference: Fluke 5520A
Automated Reference: HP 3458A
Model(s) Covered: 725Ex
This procedure contains the following tests whose Test Uncertainty Ratio
are less than 4:1. In order to improve this, we use 3458A to characterize
the 5520A in advance for some specified test points whose TUR is lower than
3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).
mA Measurement Lower and Upper
- Range 24 mA: 12 mA ; TUR1 3.0345; TUR2 18.333
- Range 24 mA: 24 mA ; TUR1 2.5660; TUR2 8.1339
Four-Wire RTD: Lower Display
- 550.0 degC; TUR 3.0000
TC Measure: Lower Display
- -180.0 degC: TUR 3.7037
TC Source: Lower Display
- -180.0 degC: TUR 3.7037
Source: Fluke 725Ex Multifunction Process Calibrator
Calibration Manual
PN 2406553, January 2005 Rev. 1,5/09
Compatibility: MET/CAL 7.20 SP1 (7.20x) or later
Additional Equipment Required:
- FLUKE-700SC Serial Interface Cable Assembly
- Fluke 724/725 Calibration Cable, Part No. 1556747
- DB9(f) to DB9(m) null modem and DB9(m) to DB9(m)
gender changer. (Only needed if UUT is connected to
55xx UUT Serial Port.
- Type J SMP plug to SMP plug thermocouple cable
Included in 5500A/LEADS, Lead Set
- MET/CAL-SERIAL, Closed Loop Procedure Serial
Connectivity Kit.
Fluke 724 (Rev >= 1.04): CAL ADJ RS-232 /5520,3458
Date: 2009-06-19 11:47:58
Revision: 1.21
Automated Reference: Fluke 5520A
Automated Reference: HP 3458A
Model(s) Covered: 724 with firmware revision 1.04 or later
Source: Fluke 724/725 Calibrators
Calibration Manual
PN 667581, September 1999 Rev.2, 2/06
Compatibility: MET/CAL 7.20 SP1 (7.20x) or later
Additional Equipment Required:
FLUKE-700SC Serial Interface Cable Assembly (1), DB9(f) to DB9(f)
null modem and DB9(m) to DB9(m) gender changer (only required if
UUT is connected to 5520 UUT Serial Port) (1)
2 ea., dual banana to separated single banana shielded cable,
Pomona Model 1368 A-30 or equivalent
Type K SMP plug to SMP plug thermocouple cable (2)
1. Included in MET/CAL-SERIAL, Closed Loop Procedure
Serial Connectivity Kit.
2. Included in 5500A/LEADS, Lead Set
Fluke 725: CAL ADJ RS-232 /5520,3458
Date: 2009-06-19 11:48:01
Revision: 1.20
Automated Reference: Fluke 5520A
Automated Reference: HP 3458A
Model(s) Covered: 725
Source: Fluke 724/725 Calibrators
Calibration Manual
PN 667581, September 1999 Rev.2, 2/06
Compatibility: MET/CAL 7.20 SP1 (7.20x) or later
Additional Equipment Required:
FLUKE-700SC Serial Interface Cable Assembly (1), DB9(f) to DB9(f)
null modem and DB9(m) to DB9(m) gender changer (only required if
UUT is connected to 5520 UUT Serial Port) (1)
2 ea., dual banana to separated single banana shielded cable,
Pomona Model 1368 A-30 or equivalent
Type K SMP plug to SMP plug thermocouple cable (2)
1. Included in MET/CAL-SERIAL, Closed Loop Procedure
Serial Connectivity Kit.
2. Included in 5500A/LEADS, Lead Set
Fluke 725Ex: CAL ADJ RS-232 /5520,3458
Date: 2009-06-19 11:48:04
Revision: 1.1
Automated Reference: Fluke 5520A
Automated Reference: HP 3458A
Model(s) Covered: 725Ex
Source: Fluke 725Ex Multifunction Process Calibrator
Calibration Manual
PN 2406553, January 2005 Rev. 1,5/09
Compatibility: MET/CAL 7.20 SP1 (7.20x) or later
Additional Equipment Required:
- FLUKE-700SC Serial Interface Cable Assembly
- Fluke 724/725 Calibration Cable, Part No. 1556747
- DB9(f) to DB9(m) null modem and DB9(m) to DB9(m)
gender changer. (Only needed if UUT is connected to
55xx UUT Serial Port.
- Type J SMP plug to SMP plug thermocouple cable
Included in 5500A/LEADS, Lead Set
- MET/CAL-SERIAL, Closed Loop Procedure Serial
Connectivity Kit.
Model(s) Covered: 724
This procedure contains the following tests whose Test Uncertainty Ratio
are less than 4:1. In order to improve this, we use 3458A to characterize
the 5520A in advance for some specified test points whose TUR is lower than
3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).
mA Measurement Lower and Upper
- Range 24 mA: 12 mA ; TUR1 3.0345; TUR2 18.333
- Range 24 mA: 24 mA ; TUR1 2.5660; TUR2 8.1339
Source: Fluke 724/725 Calibrators
Calibration Manual
PN 667581, September 1999 Rev.2, 2/06
Compatibility: MET/CAL 7.20 SP1 (7.20x) or later
Additional Equipment Required:
FLUKE-700SC Serial Interface Cable Assembly (1)
DB9 null modem adapter (1)(3)
DB9 gender changer (1)(3)
2 ea. dual banana to separated single banana shielded
cable. POMONA 1368 A-30 or equivalent
Type K SMP plug to SMP plug thermocouple cable (2)
1. Included in MET/CAL-SERIAL, Closed Loop Procedure
Serial Connectivity Kit.
2. Included in 5500A/LEADS, Lead Set
3. Only needed if UUT is connected to 5520 UUT Serial
Port.