Package: fluke_725ex_1yr_ver_rs232_5520_3458.mcz
Become a MET/SUPPORT Gold Member to download this package!

Details about Procedure Files

Below is a list of procedure files (.pro files) in the package.

Subprocedures and procedures files that only contain subprocedures have been excluded.

The references of the subprocedure files have been included.

Fluke 725Ex: (1 year) CAL VER RS-232 /5520,3458

Date: 2010-04-01 07:58:37

Revision: 1.1

Automated Reference: Fluke 5520A

Automated Reference: HP 3458A

Model(s) Covered: 725Ex

This procedure contains the following tests whose Test Uncertainty Ratio

are less than 4:1. In order to improve this, we use 3458A to characterize

the 5520A in advance for some specified test points whose TUR is lower than

3.5:1. Here is list of TUR before (TUR1) and after characterization (TUR2).

mA Measurement Lower and Upper

- Range 24 mA: 12 mA ; TUR1 3.0345; TUR2 18.333

- Range 24 mA: 24 mA ; TUR1 2.5660; TUR2 8.1339

Four-Wire RTD: Lower Display

- 550.0 degC; TUR 3.0000

TC Measure: Lower Display

- -180.0 degC: TUR 3.7037

TC Source: Lower Display

- -180.0 degC: TUR 3.7037

Source: Fluke 725Ex Multifunction Process Calibrator

Calibration Manual

PN 2406553, January 2005 Rev. 1,5/09

Compatibility: MET/CAL 7.20 SP1 (7.20x) or later

Additional Equipment Required:

- FLUKE-700SC Serial Interface Cable Assembly

- Fluke 724/725 Calibration Cable, Part No. 1556747

- DB9(f) to DB9(m) null modem and DB9(m) to DB9(m)

gender changer. (Only needed if UUT is connected to

55xx UUT Serial Port.

- Type J SMP plug to SMP plug thermocouple cable

Included in 5500A/LEADS, Lead Set

- MET/CAL-SERIAL, Closed Loop Procedure Serial

Connectivity Kit.