Package: fluke_86x_rs232_5520_33250_8508.mcz
Become a MET/SUPPORT Gold Member to download this package!
Procedures in Package
Click on the procedure names to find out details about the procedure files containing them.
Fluke 863: (1 year) CAL VER RS-232 /5520,33250, Revision: 1.5
Fluke 863: CAL ADJ RS-232 /5520, Revision: 1.3
Fluke 865: CAL ADJ RS-232 /5520, Revision: 1.3
Fluke 867: CAL ADJ RS-232 /5520, Revision: 1.3
Fluke 867B: CAL ADJ RS-232 /5520, Revision: 1.3
Fluke 865: (1 year) CAL VER RS-232 /5520,33250,8508, Revision: 1.6
Fluke 867: (1 year) CAL VER RS-232 /5520,33250,8508, Revision: 1.6
Fluke 867B: (1 year) CAL VER RS-232 /5520,33250,8508, Revision: 1.6
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
Fluke 863: (1 year) CAL VER RS-232 /5520,33250
Date: 2007-04-16 15:29:43
Revision: 1.5
Automated Reference: Agilent 33250A
Automated Reference: Fluke 5520A
Fluke 863: CAL ADJ RS-232 /5520
Fluke 865: CAL ADJ RS-232 /5520
Fluke 867: CAL ADJ RS-232 /5520
Fluke 867B: CAL ADJ RS-232 /5520
Date: 2007-04-16 15:30:07
Revision: 1.3
Automated Reference: Fluke 5520A
Model(s) Covered: 863, 865, 867, 867B
Source: Fluke 86X Calibration Procedure, Preliminary,
February 1995
867B,863 Graphical Multimeters Service Manual
PN 689312 December 1997
Compatibility: MET/CAL or 5500/CAL 7.11 or later
Additional Equipment Required:
Fluke PM9080 Optically Isolated Interface Cable
Power Adapter, BE860 (supplied with UUT)
Fluke Adapter Kit, Part No. 689486 or equivalent,
Includes DB9(f) to DB9(f) null modem adapter and
DB9(m) to DB9(m) gender changer
The average run time during testing was 23 minutes.
Fluke 865: (1 year) CAL VER RS-232 /5520,33250,8508
Fluke 867: (1 year) CAL VER RS-232 /5520,33250,8508
Fluke 867B: (1 year) CAL VER RS-232 /5520,33250,8508
Date: 2007-04-16 15:30:12
Revision: 1.6
Automated Reference: Agilent 33250A
Automated Reference: Fluke 5520A
Automated Reference: Fluke 8508A
Model(s) Covered: 865, 867, 867B
Source: Fluke 86X Performance Test Procedure, Preliminary,
February 1995
867B,863 Graphical Multimeters Service Manual
PN 689312 December 1997
This procedure contains the following tests whose Test Uncertainty Ratio
are less than 4:1.
AC Current
30 µA, 10 kHz; TUR 2.1053
2.9 A, 3 kHz; TUR 1.4710
1.0 A, 3 kHz; TUR 3.0000
2.9 A, 3 kHz; TUR 2.0645
TURs are for 5520A 90 day specifications.
Compatibility: MET/CAL 7.11b or later
Additional Equipment Required:
Fluke PM9080 Optically Isolated Interface Cable
Fluke Adapter Kit, Part No. 689486 or equivalent,
Includes DB9(f) to DB9(f) null modem adapter and
DB9(m) to DB9(m) gender changer
Cable, BNC(m)-(m)
BNC female to double stacking banana plug, Pomona 1269
The average run time during testing was 20 minutes.
Model(s) Covered: 863
Source: Fluke 86X Performance Test Procedure, Preliminary,
February 1995
867B,863 Graphical Multimeters Service Manual
PN 689312 December 1997
This procedure contains the following tests whose Test Uncertainty Ratio
are less than 4:1.
AC Current
30 µA, 10 kHz; TUR 2.1053
2.9 A, 3 kHz; TUR 1.4710
1.0 A, 3 kHz; TUR 3.0000
2.9 A, 3 kHz; TUR 2.0645
TURs are for 5520A 90 day specifications.
Compatibility: MET/CAL or 5500/CAL 7.11b or later
Additional Equipment Required:
Fluke PM9080 Optically Isolated Interface Cable
Fluke Adapter Kit, Part No. 689486 or equivalent,
Includes DB9(f) to DB9(f) null modem adapter and
DB9(m) to DB9(m) gender changer
Cable, BNC(m)-(m)
BNC female to double stacking banana plug, Pomona 1269
The average run time during testing was 20 minutes.