HP 54845A: (1 year) CAL VER IEEE /9500+1Hd,DMM, Revision: 1.1
HP 54845B: (1 year) CAL VER IEEE /9500+1Hd,DMM, Revision: 1.1
HP 54846A: (1 year) CAL VER IEEE /9500+1Hd,DMM, Revision: 1.1
HP 54846B: (1 year) CAL VER IEEE /9500+1Hd,DMM, Revision: 1.1
HP 54845A: (1 year) CAL VER IEEE /9500+5Hd,DMM, Revision: 1.1
HP 54845B: (1 year) CAL VER IEEE /9500+5Hd,DMM, Revision: 1.1
HP 54846A: (1 year) CAL VER IEEE /9500+5Hd,DMM, Revision: 1.1
HP 54846B: (1 year) CAL VER IEEE /9500+5Hd,DMM, Revision: 1.1
Details about Procedure Files
Below is a list of procedure files (.pro files) in the package.
Subprocedures and procedures files that only contain subprocedures have been excluded.
The references of the subprocedure files have been included.
HP 54845A: (1 year) CAL VER IEEE /9500+1Hd,DMM
HP 54845B: (1 year) CAL VER IEEE /9500+1Hd,DMM
HP 54846A: (1 year) CAL VER IEEE /9500+1Hd,DMM
HP 54846B: (1 year) CAL VER IEEE /9500+1Hd,DMM
Date: 2008-09-11
Revision: 1.1
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Automated Reference: Datron 9530
Automated Reference: Digital Multimeter
HP 54845A: (1 year) CAL VER IEEE /9500+5Hd,DMM
HP 54845B: (1 year) CAL VER IEEE /9500+5Hd,DMM
HP 54846A: (1 year) CAL VER IEEE /9500+5Hd,DMM
HP 54846B: (1 year) CAL VER IEEE /9500+5Hd,DMM
Date: 2008-09-11
Revision: 1.1
Automated Reference: Datron 9500
Automated Reference: Datron 9510
Automated Reference: Datron 9530
Automated Reference: Digital Multimeter
Model(s) Covered:
54845A, 54846A, 54845B, 54846B
Source:
Agilent 54835A/45A/46A Oscilloscopes Service Guide, Publication
Number 54845-97008, February 2001
Agilent 54845B/46B Oscilloscopes Service Guide, Publication Number
54846-97002, December 2001
Compatibility:
MET/CAL 7.20 SP1 (7.20x) or later
Flexible Standard(s) Required:
Digital Multimeter (DMM):
Voltage Range: 0 to 2.5 VDC
Resolution: 0.1 mV
Accuracy: ±0.05%
Example: Fluke 8845A or equivalent
Additional Equipment Required:
None
The average run time during testing was 30 minutes. (in main only)
Model(s) Covered:
54845A, 54846A, 54845B, 54846B
Source:
Agilent 54835A/45A/46A Oscilloscopes Service Guide, Publication
Number 54845-97008, February 2001
Agilent 54845B/46B Oscilloscopes Service Guide, Publication Number
54846-97002, December 2001
Compatibility:
MET/CAL 7.20 SP1 (7.20x) or later
Flexible Standard(s) Required:
Digital Multimeter (DMM):
Voltage Range: 0 to 2.5 VDC
Resolution: 0.1 mV
Accuracy: ±0.05%
Example: Fluke 8845A or equivalent
Additional Equipment Required:
Power Splitter, 1 kHz to 500 MHz, 6 dB insertion loss, output
tracking: <0.25 dB, equivalent output SWR: <1.22, HP/Agilent
11667A or equivalent
Termination, Feedthrough, BNC (f)/(m) 50 Ohms, 500 MHz, HP/Agilent
10100C or equivalent
Cable assy., 6", BNC (m)-(m), 50 Ohm, DC to 300 MHz, HP/Agilent
10502A or equivalent, 2 ea.
The average run time during testing was 30 minutes. (in main only)