HP 54845A: (1 year) CAL VER IEEE /9500+1Hd,DMM

HP 54845B: (1 year) CAL VER IEEE /9500+1Hd,DMM

HP 54846A: (1 year) CAL VER IEEE /9500+1Hd,DMM

HP 54846B: (1 year) CAL VER IEEE /9500+1Hd,DMM

Date: 2008-09-11

Revision: 1.1

Automated Reference: Datron 9500

Automated Reference: Datron 9510

Automated Reference: Datron 9530

Automated Reference: Digital Multimeter

Model(s) Covered:

54845A, 54846A, 54845B, 54846B

Source:

Agilent 54835A/45A/46A Oscilloscopes Service Guide, Publication

Number 54845-97008, February 2001

Agilent 54845B/46B Oscilloscopes Service Guide, Publication Number

54846-97002, December 2001

Compatibility:

MET/CAL 7.20 SP1 (7.20x) or later

Flexible Standard(s) Required:

Digital Multimeter (DMM):

Voltage Range: 0 to 2.5 VDC

Resolution: 0.1 mV

Accuracy: ±0.05%

Example: Fluke 8845A or equivalent

Additional Equipment Required:

Power Splitter, 1 kHz to 500 MHz, 6 dB insertion loss, output

tracking: <0.25 dB, equivalent output SWR: <1.22, HP/Agilent

11667A or equivalent

Termination, Feedthrough, BNC (f)/(m) 50 Ohms, 500 MHz, HP/Agilent

10100C or equivalent

Cable assy., 6", BNC (m)-(m), 50 Ohm, DC to 300 MHz, HP/Agilent

10502A or equivalent, 2 ea.

The average run time during testing was 30 minutes. (in main only)

HP 54845A: (1 year) CAL VER IEEE /9500+5Hd,DMM

HP 54845B: (1 year) CAL VER IEEE /9500+5Hd,DMM

HP 54846A: (1 year) CAL VER IEEE /9500+5Hd,DMM

HP 54846B: (1 year) CAL VER IEEE /9500+5Hd,DMM

Date: 2008-09-11

Revision: 1.1

Automated Reference: Datron 9500

Automated Reference: Datron 9510

Automated Reference: Datron 9530

Automated Reference: Digital Multimeter

Model(s) Covered:

54845A, 54846A, 54845B, 54846B

Source:

Agilent 54835A/45A/46A Oscilloscopes Service Guide, Publication

Number 54845-97008, February 2001

Agilent 54845B/46B Oscilloscopes Service Guide, Publication Number

54846-97002, December 2001

Compatibility:

MET/CAL 7.20 SP1 (7.20x) or later

Flexible Standard(s) Required:

Digital Multimeter (DMM):

Voltage Range: 0 to 2.5 VDC

Resolution: 0.1 mV

Accuracy: ±0.05%

Example: Fluke 8845A or equivalent

Additional Equipment Required:

None

The average run time during testing was 30 minutes. (in main only)