Package: hp_8648a_1yr_ver_ieee_8902_8903_8560_6680.mcz
Become a MET/SUPPORT Gold Member to download this package!

Details about Procedure Files

Below is a list of procedure files (.pro files) in the package.

Subprocedures and procedures files that only contain subprocedures have been excluded.

The references of the subprocedure files have been included.

HP 8648A: (2 yr) VER IEEE /8902,8903,8560,6680+9621

Date: 2008-08-05 10:28:53

Revision: 1.2

Automated Reference: HP 8560

Automated Reference: HP 8902A

Automated Reference: HP 8903B

Automated Reference: Philips PM 6680

Manual Reference: HP 11722A

Model(s) Covered:

HP/Agilent 8648A

Source:

HP 8648A/B/C/D Operation and Service Guide, Part No. 08648-90048,

April 1999

Compatibility:

MET/CAL 7.01 SP1 or later

Additional Equipment Required:

HP/Agilent 11722A Sensor Module

HP/Agilent 8903B Option 051 (CCITT Weighting filter)

Cable assy., 12", BNC(m)-(m), 50 Ohm

Cable assy., 24", Type "N"(m)-(m), 50 Ohm

Cable assy., 36", BNC(m)-(m), 50 Ohm, 2 ea.

Adapter, Type "N"(f) to BNC(m)

Adapter, tee, coaxial, BNC(f)-(m)-(f)

The average run times during testing were:

43 minutes (TUR mode)

2 hours, 31 minutes (measurement uncertainty mode)

HP 8648A: (2 yr) VER IEEE /8902,8903,8560,6680+9624

Date: 2008-08-05 10:29:03

Revision: 1.2

Automated Reference: HP 8560

Automated Reference: HP 8902A

Automated Reference: HP 8903B

Automated Reference: Philips PM 6680

Manual Reference: HP 11722A

Model(s) Covered:

HP/Agilent 8648A

Source:

HP 8648A/B/C/D Operation and Service Guide, Part No. 08648-90048,

April 1999

Compatibility:

MET/CAL 7.01 SP1 or later

Additional Equipment Required:

HP/Agilent 11722A Sensor Module

HP/Agilent 8903B Option 051 (CCITT Weighting filter)

Cable assy., 12", BNC(m)-(m), 50 Ohm

Cable assy., 24", Type "N"(m)-(m), 50 Ohm

Cable assy., 36", BNC(m)-(m), 50 Ohm, 2 ea.

Adapter, Type "N"(f) to BNC(m)

Adapter, tee, coaxial, BNC(f)-(m)-(f)

The average run times during testing were:

43 minutes (TUR mode)

2 hours, 31 minutes (measurement uncertainty mode)

HP 8648A: (2 yr) VER IEEE /8902,8903,8560,6680+9625

Date: 2008-08-05 10:29:15

Revision: 1.2

Automated Reference: HP 8560

Automated Reference: HP 8902A

Automated Reference: HP 8903B

Automated Reference: Philips PM 6680

Manual Reference: HP 11722A

Model(s) Covered:

HP/Agilent 8648A

Source:

HP 8648A/B/C/D Operation and Service Guide, Part No. 08648-90048,

April 1999

Compatibility:

MET/CAL 7.01 SP1 or later

Additional Equipment Required:

HP/Agilent 11722A Sensor Module

HP/Agilent 8903B Option 051 (CCITT Weighting filter)

Cable assy., 12", BNC(m)-(m), 50 Ohm

Cable assy., 24", Type "N"(m)-(m), 50 Ohm

Cable assy., 36", BNC(m)-(m), 50 Ohm, 2 ea.

Adapter, Type "N"(f) to BNC(m)

Adapter, tee, coaxial, BNC(f)-(m)-(f)

The average run times during testing were:

43 minutes (TUR mode)

2 hours, 31 minutes (measurement uncertainty mode)