Page 16 - Fluke Accessory Catalog
P. 16
80PK-10
These temperature probes expand the functionality of Fluke thermometers, while offering the same rugged reliability of Fluke test tools.
Temperature accessories
16
Temperature specifications
Bead
HVAC
Immersion
Surface
Air
Piercing
General purpose
Industrial surface
Pipe clamp
80BK-A
80PK-1 80PJ-1
80PK-11
80PK-22
80PK-3A
80PK-24
80PK-25 80PT-25
80PK-26
80PK-27
80PK-8
Lowest temperature
-40 °C (-40 °F)
-30 °C (-22 °F)
-40 °C (-40 °F)
0 °C (32 °F)
-40 °C (-40 °F)
Type K: -40 °C (-40 °F) Type T: -196 °C (-321 °F)
-40 °C (-40 °F)
-127 °C (-196 °F)
-29 °C (-20 °F)
Highest temperature
260 °C (500 °F)
105 °C (221 °F)
1090 °C (1994 °F)
260 °C (500 °F)
816 °C (1500 °F)
350 °C (662 °F)
816 °C (1500 °F)
600 °C (1112 °F)
149 °C (300 °F)
Probe material
Type K wire with teflon insulation
Velcro
Inconel 600
Type K sensor with teflon body
Inconel
316 Stainless Steel
304 Stainless Steel
304 Stainless Steel
Type K sensor with pvc body
Probe length
1 m lead wire
1 m lead wire
19 m Velcro cuff
21.27 cm (8.375 in)
9.525 cm (3.75 in)
21.59 cm (8.5 in)
10.16 cm (4 in)
21.57 cm (8.5 in)
20.32 cm (8 in)
for pipes from 6.4 mm (.25 in)
to 34.9 mm (1.375 in)
Cable length
1 m (39 in)
1 m (39 in)
1 m (39 in)
1 m (39 in)
1.3 m (4 ft)
1 m (39 in)
1 m (39 in)
1 m (39 in)
1 m (39 in)
1 m (39 in)
Connection
Standard banana jack
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
Molded thermocouple plug
SureGrip handle
No
No
No
Yes
No
Yes
Yes
Yes
Yes
No
Key feature
Ideal for initial troubleshoot- ing. Can be secured
in place with a magnet.
Velcro probe allows hands free temperature measurement.
For use in liquids or in gels.
Exposed junc- tion for direct contact with flat or slightly convex surfaces.
Perforated baffle for air and non-caustic gas measure- ments.
Probe material safe for use in foods. Sharp tip pierces solid surfaces.
Use for general purpose air or surface measurements.
Low conduc- tivity stainless steel mini- mizes thermal shunting. Extra rugged.
Clamps securely
to pipe. Measurements are repeatable to 0.56 °C
(1 °F).
Thermocouple types
K
K, J
K
K
K
K
K, T
K
K
K
Typical use
General purpose
•
•
•
•
•
•
•
•
•
•
HVAC
•
•
•
•
•
•
•
•
Food service
•
•
Industrial
•
•
•
•
•
Residential
•
•
•
•
•
•
Commercial
•
•
•
•
•
•
•
•
•
•