Fluke 353 and 355 AC/DC True-rms Clamp Meters
Versatile, professional, accurate
Confidently take reliable readings with the true-rms Fluke 355 and 353 Clamp Meters—the tools of choice for high current clamp-on amp meter measurements up to 2000 A.
• Reliably handle a wide range of high-current applications
with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
• Large 58 mm (2.3 in) jaw
• Inrush current measurement
• High voltage measurement of 1000 V ac + dc true-rms,
Recommended accessories
600 V ac, and 1000 V dc (355 only)
• Resistance to 400 KΩ (355 only)
• Continuity beeper (355 only)
• Frequency measurement to 1 KHz
• Selectable low-pass filter mode
• Min/Max/Avg
• Large display with backlight
Fluke 355
TL175
TwistGuardTM Test Leads See page 70
C345
Large Soft Case
See page 67
High-end industrial, utility
80TK
Thermocouple Module
See page 72
C1600
Gear Tool Box
See page 67
Fluke 355
Specifications
Measurements
Ordering information on page 17.
True
RMS
General purpose
365 373 374 375
Fluke 353
Industrial electrical
376 381
HVAC/R
iFlex accessory
i2500-10/ i2500-18
•
Leakage
360
•
902 353
355
• • • • • •
AC current ••••••• • AC voltage •••••••
Resistance •••••••
Continuity •••••••
DC volts •••••••
DC current • ••••• •
•••••••••• ••• •••
True-rms
Frequency
AC + DC voltage
AC + DC current
Min/Max/Avg ••••••••
• ••
Temperature Capacitance Special features Inrush current mode Low-pass filter
18 inch iFlex Flexible Current Probe 10 inch iFlex Flexible Current Probe Remote display
Flashlight/torch
Display
Displayhold Backlight Specifications Jaw opening Max wire size
Current range ac rms
Accuracy ac current (50/60 Hz)
AC response Current range dc Accuracy dc current
Voltage range ac Accuracy ac voltage
Voltage range dc Accuracy dc voltage
Resistance range
Frequency measurement range
•• •••
• ••• •••
• •
•• ••
•
5.7 in/3.2 in
0 to 2500 A
3 %
± 5 counts
500 Hz
Optional Optional Optional Optional
Included Optional
Included Optional •
•
••••••••• •••••••••
•
1.5 in 1250 MCM
0 to 60 A
1 %
± 5 counts
Averaging
0.7 in
17 mm (0.67 in)
0 to 200.0 A
0 to 200 A
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
1.3 in
1.3 in 750 MCM
2 % ± 5 counts
1.2 in
0 to 600.0 A
0 to 200 μA
1 %
± 5 counts
600.0 V
1 % ± 5 counts
0 to 600.0V
0 to 9999 W
2.3 in
750 MCM or three 500 MCM
0 to 1400 A 1.5 % ± 5 counts
0 to 2000 A 1.5 % ± 5 counts
0 to 600.0 V
1 %
± 5 counts
0 to 1000V
1 %
± 5 counts
0 to 400 KW 5 to 1000 Hz
0 to 600.0 A
0 to 999.9 A
True-rms 0 to 999.9 A
0 to 1000 V
0 to 1000V
0 to 60 kW 500 Hz
0 to 600.0 A
0 to 600.0 V
1 %
± 5 counts
0 to 600.0V
0 to 6000 W
2 % ± 5 counts
1.5 % ± 5 counts
1 % ± 5 counts
18