Page 25 - 810 Trianing Book Extract
P. 25












Where to mount sensors on coupled machines? Which locations are acceptable?



Exercise 4
Best answers are #2, 4, 5, 6, 7, 13, 14, 15 and 16


Horizontal pump

Measure from bearings only, not 
from the middle of the motor housing


Do Not measure from the pump 
casing. Remember, only measure 

from bearings.
If you measure from the pump 
casing, you will only see low 
noise






Not on cooling fan 

covers—metal is #2 and #16 can be good 
too thin
locations as long as you can 
place the sensor on solid 
Measure from bearings only, not 
metal, not on cooling ins or on the foundation
fan cover





Exercise 5
Best answers are #2, 3, 4, 7, 8, 9, 14, 15 and 16


Horizontal fan


Do Not measure from the fan housing. Remember, 
only measure from bearings. If you measure from 

the fan housing, you will only see low noise.




Not on cooling fan covers— 
metal is too thin










#2 and #16 can be good locations 
as long as you can place the 
sensor on solid metal, not on 
cooling ins or fan cover
Measure from bearings only, 
not on the foundation





Questions? 
t 

Review pages 70-77