Page 25 - 810 Trianing Book Extract
P. 25
Where to mount sensors on coupled machines? Which locations are acceptable?
Exercise 4
Best answers are #2, 4, 5, 6, 7, 13, 14, 15 and 16
Horizontal pump
Measure from bearings only, not
from the middle of the motor housing
Do Not measure from the pump
casing. Remember, only measure
from bearings.
If you measure from the pump
casing, you will only see low
noise
Not on cooling fan
covers—metal is #2 and #16 can be good
too thin
locations as long as you can
place the sensor on solid
Measure from bearings only, not
metal, not on cooling ins or on the foundation
fan cover
Exercise 5
Best answers are #2, 3, 4, 7, 8, 9, 14, 15 and 16
Horizontal fan
Do Not measure from the fan housing. Remember,
only measure from bearings. If you measure from
the fan housing, you will only see low noise.
Not on cooling fan covers—
metal is too thin
#2 and #16 can be good locations
as long as you can place the
sensor on solid metal, not on
cooling ins or fan cover
Measure from bearings only,
not on the foundation
Questions?
t
Review pages 70-77