Page 23 - Pressure Calibration Brochure
P. 23
Fluke 754 Documenting Fluke 750P Series
Process Calibrator-HART
Pressure Modules
The Fluke 754 Documenting The 750P Series Pressure
Process Calibrator-HART does the Modules enable gage,
work of several tools - sourcing, differential and absolute
simulating and measuring pres- pressure measurement with
sure, temperature, and electrical Fluke multifunction and
signals in one rugged, hand-held documenting process calibrators.
device. HART communication 50 pressure modules for wide
capability is combined to deliver pressure workload coverage.
an integrated communicating Best-in-class accuracies deliver
calibrator. This rugged, reli-
high confidence pressure
able tool is ideal for calibrating, measurement.
maintaining, and troubleshooting
HART smart and other process Fluke 750P Series Module features:
instrumentation.
• Compatible with 750 and 740 series DPCs and
725, 726 MPCs
Key features:
• Pressure measurement from 0 to 1 inH20 to
• Add one or more (50) 750P series pressure 10,000 psi (2.5 mbar to 690 bar).
modules to make the 754 a documenting
pressure calibrator
• Pneumatic connection adapters require no tools
to connect once adapter is mounted to test pump
• Simultaneous source/measure enables testing
of almost any process device
• Speciied for different temperature ranges to
match your working environment
• HART smart communication enables the 754 to
take on nearly all the day-to-day tasks • Reference class total uncertainties of 0.015%
performed with a separate communicator.
for 6-months. Standard module accuracies of
0.045% 0-50 degrees C for one year
• To create a seamless/paperless calibration
management system add the Fluke DPCTrack2 • 3 year warranty
Calibration Management software
Application coverage
• 3-year warranty
• Differential modules measure differential pres-
Summary specs
sure from 0-1 inH2O to 15 psi, 2.5 mbar to 1 bar
• Source: mA, DC voltage, frequency, resistance, • Gage modules measure gage pressure from 30 to
thermocouples, RTDs
2,000 psi, 2 to 140 bar
• Measure: mA, mA with loop power, AC voltage, • High pressure modules measure pressure from
DC voltage, frequency, thermocouples, RTDs
3,000 to 10,000 psi, 200 to 700 bar
• CAT II 300V overvoltage protection, measure up • Absolute modules measure absolute pressure
to300Vac
from 5 to 1,500 psia, 350 mbar to 100 bar abso-
lute
Application coverage
• Vacuum modules measure gage vacuum pressure
• Pressure and temperature transmitter calibration
from -5 psi to -15 psi, -350 mbar to -1 bar
• Pressure and temperature switch test
• Dual range modules measure pressure from -1 to
and calibration
+ 1 psi to -15 to 300 psi -70 to + 70 mbar to -1
• I/P transducers and control valves test bar to 20 bar
and calibration
• Reference class accuracy modules measure from
• Verify process I/O with mA and voltage 15 psi to 10,000 psi, 1 bar to 700 bar
source/simulate/measure
• Add a Fluke Calibration dry block for full loop
temperature calibration
• Test results for upload/download for paperless
calibration management
23