Page 25 - Fluke Accessory Catalog
P. 25

Left to right: i410, 80i-110s, i30
AC/DC clamp-on current probe compatibility
Model number 80i-110s i410 i1010 i30 10/11/12/ 0.1Ato100Adc/ 5Ato400Adc/ 5Ato1000Adc/ 40mAto30Adc/
12B/16/18 0.1 A to 70 A ac* 7 A to 400 A ac 7 A to 600 A ac 60 mA to 20 A ac 110/111/112 0.14Ato100Adc/ 5Ato400Adc/ 5Ato1000Adc/300 40mAto30Adc/
i30s
40mAto30Adc/ 60 mA to 20 A ac
40mAto30Adc/ 3 A to 20 A ac
30mAto30Adc/ 60 mA to 20 A ac
30mAto30Adc/ 40 mA to 20 A ac
30mAto30Adc/ 200mAto20Aac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 40 mA to 20 A ac
30mAto30Adc/ 300mAto20Aac
30mAto30Adc/ 300mAto20Aac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 200mAto20Aac
30 mA to 30 A dc/ 30 mA to 20 A ac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 200mAto20Aac
30mAto30Adc/ 300mAto20Aac
Usable but will read 100 times higher
i310s
0.4Ato450Adc/ 0.6 A to 300 A ac
0.4Ato450Adc/ 30 A to 300 A ac
0.1Ato450Adc/ 0.6 A to 300 A ac
0.1Ato450Adc/ 0.4 A to 300 A ac
0.1Ato450Adc/ 2 A to 300 A ac
0.1Ato450Adc/ 0.1 A to 300 A ac
0.1Ato450Adc/ 0.4 A to 300 A ac
0.1Ato450Adc/ 3 A to 300 A ac
0.1Ato450Adc/ 3 A to 300 A ac
0.1Ato450Adc/ 0.1 A to 300 A ac
0.1Ato450Adc/ 2 A to 300 A ac
0.1 A to 450 A dc/ 0.25 A to 300 A ac
0.1Ato450Adc/ 0.1 A to 300 A ac
0.1Ato450Adc/ 2 A to 300 A ac
0.1Ato450Adc/ 3 A to 300 A ac
Not spec’d for dc 0.6 A to 300 A ac
0.1Ato450Adc/ 0.5 A to 300 A ac
0.1Ato450Adc/ 2.5 A to 300 A ac
0.1Ato450Adc/ 0.5 A to 300 A ac
0.1Ato450Adc/ 1.5 A to 300 A ac
0.1Ato450Adc/ 0.2 A to 300 A ac
0.1Ato450Adc/ 0.1 A to 300 A ac
25
114/115/116/117
21/23/70/73/ 75/77 Series III
26/79 Series III
27
77-IV
175/177/179
1577/1587
83-III/83-V/88-V
85-III/87-III/87-V
87-IV/89-IV/ 187/189
287/289 8060A/8062A 860 Series 39/41B
9X Series
120 Series 190 Series
45 DMM 8808A 8845A/8846A 705/707
715
74X Series 787/789
3 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.2 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.11 A to 100 A dc/ 0.3 A to 70 A ac*
0.1Ato100Adc/ 0.3 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.2 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.2 A to 70 A ac*
0.1Ato100Adc/ 0.3 A to 70 A ac*
Usable but will read 10 or 100 times higher
0.1Ato100Adc/ 0.1 A to 70 A ac
0.1Ato100Adc/ 0.25 A to 70 A ac
0.1Ato100Adc/ 0.1 A to 70 A ac
0.1Ato100Adc/ 0.15Ato70Aac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1Ato100Adc/ 0.1 A to 70 A ac*
0.1 A to 100 A dc, no ac*
0.1 A to 100 A dc, no ac*
0.1Ato100Adc/ 1.1 A to 70 A ac*
0.1Ato100Adc/ 0.2 A to 70 A ac*
300 A to 400 A ac A to 600 A ac 3 A to 20 A ac 1.4Ato400Adc/ 1.4Ato1000Adc/ 30mAto30Adc/
6 A to 400 A ac
1Ato400Adc/ 5 A to 400 A ac
1Ato400Adc/ 20Ato400Aac
1Ato400Adc/ 1 A to 400 A ac
1Ato400Adc/ 5 A to 400 A ac
1.6 A to 400 A dc/ 30 A to 400 A ac
1.2 A to 400 A dc/ 30 A to 400 A ac
1Ato400Adc/ 1 A to 400 A ac
1Ato400Adc/ 20Ato400Aac
1 A to 400 A dc/ 2.5 A to 400 A ac
1Ato400Adc/ 1 A to 400 A ac
1Ato400Adc/ 20Ato400Aac
1Ato400Adc/ 30Ato400Aac
1 A to 400 A ac** Not spec’d for dc
1 A to 400 A dc/ 5 A to 400 A ac**
6 A to 600 A ac
1Ato1000Adc/ 5 A to 600 A ac
1Ato1000Adc/ 20 A to 600 A ac
1Ato1000Adc/ 1 A to 600 A ac
1Ato1000Adc/ 5 A to 600 A ac
1.6 A to 1000 A dc/ 30 A to 600 A ac
1.2 A to 1000 A dc/ 30 A to 600 A ac
1Ato1000Adc/ 1 A to 600 A ac
1Ato1000Adc/ 20 A to 600 A ac
1Ato1000Adc/ 2.5Ato600Aac
1Ato1000Adc/ 1 A to 600 A ac
1Ato1000Adc/ 20 A to 600 A ac
1Ato1000Adc/ 30 A to 600 A ac
1 A to 600 A ac** Not spec’d for dc
1Ato1000Adc/ 5 A to 600 A ac**
60 mA to 20 A ac
30mAto30Adc/ 40 mA to 20 A ac
30mAto30Adc/ 200mAto20Aac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 40 mA to 20 A ac
30mAto30Adc/ 300mAto20Aac
30mAto30Adc/ 300mAto20Aac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 200mAto20Aac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 30 mA to 20 A ac
30mAto30Adc/ 200mAto20Aac
30mAto30Adc/ 300mAto20Aac
Usable but will read 100 times higher**
30mAto30Adc/ 30mAto30Adc/ 50 mA to 20 A ac** 50 mA to 20 A ac
1Ato400Adc/ 1Ato1000Adc/ 30mAto30Adc/ 30mAto30Adc/ 25Ato400Aac** 25Ato600Aac** 250mAto20Aac** 250mAto20Aac
1 A to 400 A dc/ 5 A to 400 A ac**
1Ato400Adc/ 15Ato400Aac
1Ato400Adc/ 2 A to 400 A ac
1Ato400Adc/ 1 A to 400 A ac
1 A to 1000 A dc/ 5 A to 600 A ac**
1Ato1000Adc/ 15 A to 600 A ac
1Ato1000Adc/ 2 A to 600 A ac
1Ato1000Adc/ 1 A to 600 A ac
30mAto30Adc/ 30mAto30Adc/ 50 mA to 20 A ac** 50 mA to 20 A ac
30 mA to 30 A dc 30 mA to 30 A dc 150mAto20Aac 150mAto20Aac
30mAto30Adc/ 30mAto30Adc/ 30 mA to 20 A ac 30 mA to 20 A ac
30mAto30Adc/ 30mAto30Adc/ 30 mA to 20 A ac 30 mA to 20 A ac
4Ato400Adc,noac 4Ato1000Adc,noac 40mAto30Adc,noac 40mAto30Adc,noac 0.4Ato450Adc,noac 4Ato400Adc,noac 4Ato1000Adc,noac 40mAto30Adc,noac 40mAto30Adc,noac 0.1Ato450Adc,noac
1 A to 400 A dc/ 110 A to 400 A ac
1 A to 400 A dc/ 20 A to 400 A ac
1 A to 1000 A dc/ 110 A to 600 A ac
1 A to 1000 A dc/ 20 A to 600 A ac
30 mA to 30 A dc/ 1.1 A to 20 A ac
30 mA to 30 A dc/ 200 mA to 20 A ac
30 mA to 30 A dc/ 1.1 A to 20 A ac
3 mA to 30 A dc/ 200 mA to 20 A ac
0.1 A to 450 A dc/ 11 A to 300 A ac
0.1 A to 450 A dc/ 2 A to 300 A ac
*Requires PM9081/001 Adapters. **Requires PM9082/001 Adapter
For more information, go to www.fluke.com/accessories


































































































   23   24   25   26   27