Page 24 - Fluke Accessory Catalog
P. 24
i1010
Current clamps: AC/DC
24
AC/DC current clamp specifications
i30
i30s
80i-110s
i310s
i410
i1010
DC range
30 mA to 30 A
30 mA to 30 A
0.1 A to 100 A
0.1 A to 450 A
1 A to 400 A
1 A to 1000 A
AC range
30 mA to 20 A rms
30 mA to 20 A rms
0.1 A to 70 A
0.1 A to 300 A
1 A to 400 A
1 A to 600 A
Accuracy
± 1 % of reading, ± 2 mA
± 1 % of reading, ± 2 mA
0.1 A to 10 A; dc to 1 kHz:
± 3 % + 50 mA; up to 100 A add 15 %;
up to 20 kHz add 12 %
30 A range: 1 % + 50 mA 300 A range: 1 % + 300 mA
3.5 % + 0.5 A for dc or ac (45 Hz to 400 Hz)
2 % + 0.5 A for dc or ac (45 Hz to 400 Hz)
Bandwidth (-3 dB)
dc to 20 kHz (-0.5 dB)
dc to 100 kHz (-0.5 dB)
100 kHZ
dc to 20 kHz
3 kHz
10 kHz
Zero error adjustment
Yes
Yes
Yes
Yes
Yes
Yes
Maximum conductor diameter
19 mm (0.75 in)
19 mm (0.75 in)
11.8 mm (0.46 in)
19 mm (0.75 in)
30 mm (1.18 in)
30 mm (1.18 in)
Maximum conductor size
250 MCM
250 MCM
1 AWG
250 MCM
750 MCM or 2-500 MCM
750 MCM or 2-500 MCM
Output levels
100 mV/A
100 mV/A
10 mV/A, 100 mV/A
10 mV/A, 100 mV/A
1 mV/A
1 mV/A
Output cable
1.5 meter with shrouded dual banana plug
2 meter with BNC termination
1.6 meter with BNC termination
2 meters with BNC termination and a BNC to safety shrouded banana adapter
1.2 meter with shrouded banana plugs
1.2 meter with shrouded banana plugs
Battery life (hours)
30
30
40
30
60
60
Warranty
One-year
One-year
One-year
One-year
One-year
One-year
Safety
CAT III 300 V
CAT III 300 V
CAT II 600 V, CAT III 300 V
CAT III 300 V
CAT III 600 V
CAT III 600 V