Page 32 - Fluke Test Tools Catalog
P. 32
Fluke 430-II Series Three-Phase Power Quality Analyzers
The new Fluke 434-II, 435-II and 437-II help locate, predict, prevent and troubleshoot power quality prob- lems in three- and single-phase power distribution systems. Additionally, the Fluke-patented energy loss algorithm, Unified Power Measurement, measures, quantifies and monetizes energy losses due to harmon- ics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.
• Patented energy loss management: Classic active and reactive power measurements unbalance and harmonic power and energy are quantified to pin- point true system energy losses.
• Realtime PowerWave data capture: Capture fast rms data, show single cycle rms value to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
• Highest safety rating in the industry: CAT IV 600 V/ CAT III 1000 V rated for use at the service entrance
• Automatic transient mode: Capture 200 kHz wave- form data on all phases simultaneously up to 6 kV
• Fully Class-A compliant: Conduct tests according to
the stringent international IEC 61000-4-30 Class-A
standard intervals for 435-II and 437-II
• Troubleshoot real-time: Analyze the trends using
the cursors and zoom tools—even while background
recording continues
• Measure all three phases and neutral: With
included four iFlex flexible current probes
• Monetize energy loss caused by power quality issues
• Wi-Fi SD Card compatible: Download data wirelessly
(not included)
Recommended accessories
I5sPQ3
3 pack of 5 A precision current clamps
GPS430
GPS time synchronization module
C437-II
Water-tight hard case with rollers
Energy loss calculator
Useful kilowatts (power available)—Effective kW Reactive (unusable) power—Reactive kvar Kilowatts made unusable by unbalance issues—Unbalance kVA Kilowatts made unusable by harmonics—Distortion kVA Neutral Current—Neutral Total cost of wasted kilowatt hours
Features
Features
434-II
435-II
437-II
Measures voltage, current, dips, swells, interruptions, harmonics, power, energy loss monetization, frequency, inrush and power inverter efficiency
•
•
•
Flicker
•
•
Transients
•
•
Mains signaling
•
•
Power wave
•
•
Event waveform capture
•
•
400 Hz
•
C1740 Soft Case
•
•
C437-II Hard Case with rollers
•
SD card (Max 32 GB)
8 GB
8 GB
8 GB
Ordering information (basic versions do not include current probes)
Fluke CarePlans www.fluke.com/Care-Plans
Maintain your test tool in top operating condition and control your cost of ownership with a Fluke CarePlan.
Included accessories
Models
Four thin flexible current probes (i430-TF), five test leads and clips, battery charger, Power Log software, USB cable, color localization set, soft carrying case, 8 GB SD memory card, users manual on CD.
FLUKE-434-II Three-Phase Energy Analyzer
FLUKE-435-II Three-Phase Power Quality and Energy Analyzer
Four thin flexible current probes (i430-TF), five test leads and clips, battery charger, Power Log software, USB cable, color localization set, hard carrying case with wheels, 8GB SD memory card, users manual on CD.
FLUKE-437-II 400 Hz Three-Phase Power Quality and Energy Analyzer
30
Power Quality Analyzers
For more information, go to www.fluke.com/pq
Check price and availability at
www.fluke.com/wtb