Page 37 - Fluke Test Tools Catalog
P. 37
Pick the right process tool for you
Process Tools Selection Guides
Models
Measure
V dc
V ac (true-rms) Resistance
A dc
A ac Frequency Pressure
Temperature: RTDs Temperature: TCs Source/Simulate V dc
Process mA Clamp Meter
773
30 V
20.99, 99.9 mA
10 V 24 mA
•
ProcessMeter® Test Tool
789
1000 V 1000 V 40 MW 30 mA, 1 A •
20 kHz
Loop Calibrator 709H
30 V
24 mA
Pressure Calibrator
719/719PRO
24 mA
30 psi, 150 psi, 300 psi
719Pro optional
Temperature Calibrator
724
30 V
3200 W 24 mA
7 types 12 types
10 V 3200 W
7 types 12 types
Precision Multifunction Process Calibrator
726
30 V
4000 W 24 mA
15 kHz
•1
8 types 13 types
20 V 4000 W 24 mA •
15 kHz 8 types 13 types
Intrinsically Safe Calibrator
725Ex
30 V
3200 W 24 mA
10 kHz
•5
7 types 12 types
10 V 3200 W 24 mA •
10 kHz 7 types 12 types
Documenting Process Calibrator
754
300 V 300 V 11 kW 110 mA
50 kHz
•1
8 types 13 types
15 V 11 kW 22 mA •
50 kHz 8 types 13 types
• • • • •
• •
Three-year
• •
Resistance
mA dc
mA source; auto step, auto ramp
Frequency
Temperature: RTDs
Temperature: TCs
Record
Min/Max • • Hold••• As found/As left results
Log data
Upload data to PC
Remote operation
Features
24Vloopsupply
Non-contact mA measurement
HART communication
Integrated hand pressure pump
Intrinsically safe (ATEX) Warranty
Traceable calibration certification
Accessories3
Pressure enabled4
Seepage
Three-year
Three-year
A/B
•
Three-year
•
A/B
Electric Three-year
•
C
•
Three-year
•
•
Three-year Three-year
• •
•
•••• •
24 mA
•
•
24 mA
•
• •
24 mA
•
• • • •
•
• • • 12V
36 37 39 44 41 40 47 39
1Fluke 750P Pressure Modules required.
2Either the internal sensor or a Fluke 700 Pressure Module may be used.
3Accessories: A. Compatible with LockPak B. Compatible with TPAK C. Accepts hanging straps from TPAK D. Optional accessories. 4Fluke Process Calibrators in this guide displaying the Pressure Enabled symbol display readings from the 750P Series Pressure Modules. 5Fluke 700PEx Pressure Module required.
9103/ 9140/ 9141
–25 °C to 650 °C
Temperature
Pressure • ••
Humidity •
DC volt/current
Source
Temperature
Pressure
Thermocouple
Features
Min/Max
Log data
See Page 42 46 43 42 40 42 46 46 46 42
Model
Range
Measure
914X/9190A
–95 °C to 660 °C
P3000
To 60,000 psi (400 MPa)
152X
–200 °C to 420 °C
418X
–15 °C to 500 °C
1620A
0 °C to 50 °C; 20 % to 70 %
P5500
To 20,000 psi (70 MPa)
3130
Vacuum to 300 psi
2700G
–15 psi to 10,000 psi (70 MPa)
1586A
Various
• •••
• ••
• •••
• • • • • ••
For more information, go to www.fluke.com/processtools Process Calibration Tools 35
A/B A/B
•
•