Page 44 - Fluke Test Tools Catalog
P. 44
Fluke Calibration Temperature Sources
9142/9143/9144 Field Metrology Wells
Small dry wells for big field applications
Applications: Temperature instrument calibration, 4 to 20 ma loop test and calibration, temperature switch testing.
• Lightweight, portable, and fast
• Cool to -25 °C in 15 minutes and heat to 660 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
• Stability to ± 0.01 °C
• Accredited calibration
9103/9140/9141 Field Dry-Well Calibrators
Portable instruments with great performance
Applications: Temperature instrument calibration, tem- perature switch tests.
• Lightweightandveryportable
• Three models ranging from -25 °C to 650 °C
• Accuracy to ± 0.25 °C • Stability to ± 0.02 °C
4180/4181 Precision Infrared Calibrators
Accredited performance for point-and-shoot calibrations
Applications: Infrared thermometer calibration.
• Calibrated radiometrically for meaningful, consistent
results
• Accredited calibration accurate to ± 0.35 °C
• Wide coverage -15 °C to 500 °C
• Stability to ± 0.01 °C
Ordering information
9190A Ultra-Cool Field Metrology Well
Ultra-cool dry-block calibrator with best-in-class stability Applications: Temperature instru- ment calibration, 4-20 mA loop test and calibration.
• Wide temperature range: -95 °C to 140 °C
• Accuracy to ± 0.05 °C
• Fast cooling time to -95 °C:
90 minutes
Recommended accessories
Specialty models
9142-CASE 1620A
Carrying Case Digital Thermometer- Hygrometer
Recommended accessories
4180-CASE 4180-DCAS
Carrying Case Carrying Case w/wheels
Included accessories
Models
Specify included insert
Insert, insert removal tool, software, calibration certificate
9103
Field Dry-Well Calibrator, –25 °C to 140 °C
Insert A: 1/16” (1.6 mm), 1/8” (3.2 mm), 3/16” (4.8 mm), 1/4” (6.35 mm),
3/8” (9.5 mm) and 1/2” (12.7 mm)
9140
Field Dry-Well Calibrator, 35 °C to 350 °C
Insert C: 6 at 1/4” (6.35 mm)
9141
Field Dry-Well Calibrator, 50 °C to 650 °C
Included accessories
Models
Well inserts
Insert, insert removal tool, manual, software,USB cable, accredited calibration certificate
9190A
Field Metrology Well, -95 °C to 140 °C
9190A-INSA Insert A, 9190A, misc holes 9190-INSC Insert C, 9190, 6 x 0.25 in holes
9190A-P
Field Metrology Well, -95 °C to 140 °C, process version
Included accessories
Models
Well inserts
Insert, insert removal tool, test lead kit (process version), software, manual, accredited calibration certificate
9142-X Field Metrology Well, -25 °C to 150 °C
9142-INSA 9142-INSB 9142-INSC
Insert A, 9142, misc holes
Insert B, 9142, comp holes Insert C, 9142, 6 x 0.25 in holes
9142-P Field Metrology Well, -25 °C to 150 °C, process version
9143 Field Metrology Well, 33 °C to 350 °C
9143-INSA 9143-INSB 9143-INSC
Insert A, 9143, misc holes
Insert B, 9143, comp holes Insert C, 9143, 6 x 0.25 in holes
9143-P Field Metrology Well, 33 °C to 350 °C, process version
9144 Field Metrology Well, 50 °C to 660 °C
9144-INSA 9144-INSB 9144-INSC
Insert A, 9144, misc holes
Insert B, 9144, comp holes Insert C, 9144, 6 x 0.25 in holes
9144-P Field Metrology Well, 50 °C to 660 °C, process version
Included accessories
Models
Report of Calibration (NVLAP accredited), power cord, user’s guide, documentation CD, target cover, serial cable.
4180 Precision Infrared Calibrator, –15 °C to 120 °C
4181 Precision Infrared Calibrator, 35 °C to 500 °C
Included accessories
Models
Accessories vary by model. For details see www.flukecal.com/DewK
1621A “DewK” Thermo-Hygrometer*
1622A “DewK” Thermo-Hygrometer*
42
Process Calibration Tools For more information, go to www.fluke.com/tempcal
*Each model comes in “-H” version (High-Accuracy Value Kit) and “-S” version (Standard-Accuracy Value Kit).
Check price and availability at
www.fluke.com/wtb


































































































   42   43   44   45   46