Page 59 - Fluke Test Tools Catalog
P. 59
Specifications
Ti125
2 megapixel industrial-grade
Ti110
Ti105
Ti100
46 cm (18 in)
Ti95
2 megapixel industrial-grade
Ti90
Temperature measurement
Temperature measurement range (not calibrated below -10 °C)
Temperature measurement ac- curacy
On-screen emissivity correction
On-screen reflected background temperature compensation
On-screen transmission correction Imaging performance
Image capture frequency Resolution
Thermal sensitivity (NETD)
Infrared spectral band Visual (visible light) camera Field of view
Spatial resolution (IFOV) Minimum focus distance Focus mechanism
Focus system
Image presentation Palettes: Standard
Palettes: Ultra ContrastTM
Level and span IR-Fusion® information Picture-In-Picture (PIP)
AutoBlendTM mode
Color alarms (temperature alarms)
Image capture and data storage
Image capture, review, save mechanism
Storage medium File formats: Image File formats: Video Export file formats
Other time-saving and productivity features Voice annotation
IR-PhotoNotesTM
Wi-Fi connectivity
Electronic (cardinal) Compass Video recording*
Streaming video
Fluke Connect compatible General specifications Ruggedized display
Controls and adjustments
Software
Batteries (field-replaceable, rechargeable)
Battery life
Battery charge time AC battery charging AC operation
Safety standards Vibration/Shock/ Drop Enclosure rating Warranty
-20 °C to +350 °C (-4 °F to +662 °F)
-20 °C to +250 °C (-4 °F to +482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
•
•
•
9 Hz or 30 Hz versions
9 Hz only
160 x 120 (19,200 pixels)
≤ 0.10 °C at 30 °C target temp (100 mK)
80 x 80 (6,400 pixels)
80 x 60 (4,800 pixe
ls)
≤ 0.15 °C at 30 °C target temp (150 mK)
19.5 °H x 26 °V
d
Blue-red, grayscale, ironbow
≤ 0.10 °C at 30 °C target temp (100 mK) Filtered mode to get to 80 mK
7.5 μm to 14 μm (long wave)
9 μm to 15 μm (long wave)
None - IR Only
22.5 °H x 31 °V
26 °H x 26 °V
3.39 mRad
5.6 mRad
15.25 cm (6 in)
IR-OptiFlexTM focus system
Focus-free 1.2 m (4 ft) and beyond
Focus-free 0.6 m (2 ft) and beyon
Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber
Blue-Red, Ironbow, Grayscale, Amber
Blue-red, grayscale, high- contrast, hot metal, ironbow, amber
Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Blue-Red, Grayscale, Ironbow
Manual and auto
•
PIP (1.2 m (4 ft) to 4.6 m (15 ft))
PIP (1.2 m (4 ft) to 4.6 m (15 ft))
High temperature, low temperature, isotherm
•
Yes (Mid IR Mode)
High temperature, low temperature
High temperature
One-handed image capture, review, and save capability
SD memory card, 8 Gb WiFi SD Card (where available), direct download via USB-to-PC connection
.IS2, .BMP, .JPEG
.IS3, .AVI
.AVI
(w/SmartView®software) BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
• (60 seconds) per image
Yes (3 images)
Yes, with included WiFi SD Card
•
Yes (AVI with MPEG encoding, up to 5 minutes)
Streaming via USB to PC
Yes, with included WiFi SD Card
3.5 inch diagonal (portrait format)
User selectable hot spot and cold spot markers, 3 user definable spot mark- ers on camera and in Smartview®, and center point on image, expand- able-contractable and measurement box with MIN/MAX/AVG temp
Three user defin- able spot markers
on camera and in Smartview®, and center point on image expandable-contrac- table and measure- ment Box with MIN/ MAX/AVG temp
Three user definable spot markers on cam- era and in Smartview®, and center point on image, expandable- contractable, measure- ment Box with MIN/ MAX/AVG temp
Center point tempera- ture measurement
Center point tem- perature measurement, fixed-size, measure- ment box with MIN/ MAX/AVG temp
Center point tempera- ture measurement
SmartView® and SmartView Mobile App - full analysis and reporting software
Two
Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
One
2.5 hours to full charge
Included
AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz).
Optional accessory
CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
2G, IEC 68-2-6/ 25G, IEC 68-2-29/ 2 meter (6.5 feet)
IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Two-years (standard), extended warranties are available.
For more information, go to www.fluke.com/thermal_imaging