Page 61 - Fluke Test Tools Catalog
P. 61
Fluke IR-Windows
Installation in less than five minutes
Fluke CV300
Fluke CLKT
Why open enclosures and expose yourself to arc flash hazards when you don’t have to? Safety shouldn’t be secondary.
NFPA 70E compliant infrared inspections
are time consuming and painful without IR Windows. Skip the headache of lock-out/tag- out, live work permits and cumbersome PPE. IR Windows provide increased safety, speed and frequency of inspection.
Our new design delivers groundbreaking benefits:
• Under five minute installation with one
person, no need to remove panel door
• AutoGroundTM technology instantly grounds
window to enclosure upon installation
• Highest arc blast safety rating available—
63 kA
• IP67 for years of maintenance free operation
in any environmental condition
• ClirVu® coating protects the optic from
the elements while providing a clear, unobstructed view of the equipment for visual inspections
Specifications
Model CV400
CV401
CV300
CV301
CV200
CV201
CLKT
Size 95 mm (4 in)
75 mm (3 in)
50 mm (2 in)
100 mm, 75 mm and 50 mm (4, 3 and 2 in)
Voltage range Any
Any
NEMA environment type Type 4/12 (indoor/outdoor)
Type 3/12
AutoGroundTM •
•
ClirVu® Optic •
•
Operating temperature
-40 °C to +232 °C (-40 ° Fto +450 °F) and +260 °C (500 °F) intermittent
-40 °C to +232 °C (-40 ° F to +450 °F)
Arc-Tested (IEEE C37.20.7) 63 kA for 30 cycles @ 60 Hz at KEMA
50 kA for 30 cycles @ 60 Hz at KEMA
UL 50 V component recognition
•
•
UL 50 /NEMA environmental rating
NEMA Type 4/12
NEMA Type 3/12
UL1558 •
CSA C22.2 No. •
•
CSA type rating Type 4
Type 3/12
IP rating IP67 at TUV
IP55
Lloyds Register Up to 11 kV marine switchgear, indoor or outdoor (offshore only)
Vibration rating IEC60068-2-6 at TUV
IEC60068-2-6
Humidity rating IEC60068-2-3 at TUV
IEC60068-2-3
Actual mounting hole diameter required
115.42 mm (4.544 in)
89.89 mm (3.539 in)
61.37 mm (2.416 in)
50 mm 43.2 mm (1.7 in); 75 mm 69.9 mm (2.75 in); 100 mm 92 mm (3.62 in)
Greenlee Punch kit = 742BB = 2984AV / Punch/die 2983AV
739BB = 1431AV / 1432AV
76BB = 441AV / 442AV
50 mm 06974/04013; 75 mm 04247/04246; 100 mm hole, saw only
Door latch
Hand turn
Security key
Hand turn
Security key
Hand turn
Security key
Hand turn
Optic insert diameter 95 mm (3.74 in)
75 mm (2.96 in)
50 mm (1.97 in)
100 mm, 75 mm and 50 mm (4, 3 and 2 in)
Warranty Lifetime replacement against manufacturing defects
Ordering information
Included accessories
Models
Installation CD, self-adhesive drilling template, warranty statement and security key if that option is ordered.
CV401 95 mm (4 in) IR Window, Security Key Door Latch
CV400 95 mm (4 in) IR Window, Hand Turn Door Latch
CV301 75 mm (3 in) IR Window, Security Key Door Latch
CV300 75 mm (3 in) IR Window, Hand Turn Door Latch
CV201 50 mm (2 in) IR Window, Security Key Door Latch
CV200 50 mm (2 in) IR Window, Hand Turn Door Latch
Installation CD, self-adhesive drilling template, security access key, warranty statement.
FLK-075-CLKT 75 mm (3 in) C-Range IR Window, Kwik Twist
FLK-050-CLKT 50 mm (2 in) C-Range IR Window, Kwik Twist
FLK-100-CLKT 100 mm (4 in) C-Range IR Window, Kwik Twist
For more information, go to www.fluke.com/thermal_imaging
Infrared Cameras
59
Entry Level and Advanced Infrared Training Solutions
Unsure where to begin with your new infrared camera? Looking to take your training to the next level? Don’t worry. Fluke has partnered with The Snell Group, a leading ther- mographic training company with knowledge of the Fluke family of infrared cameras. They offer Level 1, Level 2 and Level 3 training as well as in-depth application training that can help make you an expert in no time.
Visit www.fluke.com/titraining for a portfolio of training solutions including:
• Free online webinars
• Hands-on training seminars • Advanced training
Fluke authorized training is provided by our partner,
Check price and availability at
www.fluke.com/wtb