Page 40 - Fluke Test Tools Catalog
P. 40
Fluke 715, 707 and 705 Loop Calibrators
Complete family of volt/mA calibrators
Fluke 715 Volt/mA Calibrator
• Source voltage to 200 mV or 20 V
• Measure loop current (0-20 mA, 4-20 mA) signals
with 0.01 % accuracy and 1 μA resolution
• Measure voltage output process signals from PLCs,
transmitters
• Source or simulate 4-20 mA loop current
• 24 V loop supply with simultaneous current
measurement
• Ramp and Step Ramp output functions
Fluke 707 and 705
• Innovative output adjustment dial on 707 provides
1 μA and 100 μA resolution and one-hand operation
• Large display and simple interface for ease of use
• Simultaneous mA and % readout for quick, easy
Specialty models
709H Precision HART
Loop Calibrator
See page 39 for more information.
Recommended accessories
Fluke 715
interpretation of readings
• mA accuracy of 0.015 % on the Fluke
707 and 0.02 % on the 705
• HARTTM mode on 707 connects 250
ohm resistor in series with 24 V loop for compatibility with HART communicators
• Push button 25 % steps for fast, easy linearity checks
• “Span Check” for fast confirmation of zero and span
• Selectable slow and fast linear step ramp provide ramping outputs for valve slewing, remote testing and loop functional tests
• 24 V internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
• 0-20 mA or 4-20 mA default start up modes
Specifications
Fluke 707
TL28A
Heavy Duty Test Lead Set
C550
Tool Bag
See page 67
TL220
SureGrip Industrial Test Lead Set See page 68
PV350
Pressure Vacuum Module
See page 76
Fluke CarePlans www.fluke.com/Care-Plans
Functions
Fluke 705 and 707
Fluke 715
Voltage measurement
Range
0 V to 28 V
0 mVto 200 mV
0 V to 25 V
Resolution
1 mV
10 μV
1 mV
Accuracy
705: 0.025 % Rdg + 1 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD
0.01 % Rdg + 2 LSD
Current measurement
Range
0 mA to 24 mA
0 mA to 24 mA
Resolution
0.001 mA
0.001 mA
Accuracy
705: 0.02 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD
0.01 % + 2 LSD
Current sourcing
Range
0 mA to 20 mA or 4 mA to 20 mA
0 mA to 20 mA or 4 mA to 20 mA
Accuracy
705: 0.025 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD
0.01 % Rdg + 2 LSD
Drive capability
705: 1000 W @ 24 mA 707: 1200 W @ 24 mA 707Ex: 700 W @ 20 mA
1000 W @ 24 mA
Loop power while measuring mA
24 V
24 V
Voltage sourcing
0 mV to 200 mV or 0 V to 20 V
Display current and % of span
•
mA or %
Auto step, auto ramp
•
•
Span Check
•
•
Battery life
18 hours typical, at 12 mA
18 hours typical, at 12 mA
Warranty
Three-year
Ordering information
Included accessories
Models
Test leads, alligator clips, holster, traceable calibration report and data, single 9 V alkaline battery, instruction sheet (14 languages).
FLUKE-715 Volt/mA Calibrator
FLUKE-707 Loop Calibrator
FLUKE-707Ex Intrinsically Safe Loop Calibrator
FLUKE-705 Loop Calibrator
38
Process Calibration Tools
For more information, go to www.fluke.com/loop
Check price and availability at
www.fluke.com/wtb