Page 41 - Fluke Test Tools Catalog
P. 41
Fluke 753 and 754 Calibrators
Calibrate/troubleshoot process control instrumentation
Fluke 754
• Calibrate temperature, pressure, voltage, current, resistance and frequency instruments
• Built-in procedures for transmitters, square root transmitters, pressure and temperature switches
• Simultaneously measure and source
• Automatically capture calibration results
• Document procedures and results to meet ISO
9000, EPA, FDA, OSHA and other requirements
• Measure/simulate 13 types of thermocouples and
eight RTDs
• Store up to 8,000 readings in data logging mode
• Protected against dirt, dust and moisture;
unaffected by vibration
• Includes a USB interface
• Operate in English, French, German, Italian and
Spanish
• One- and two-year calibration cycles and a
three-year warranty
754: Get HART-abilityTM
The Fluke 754 offers all of the capabilities of the 753, plus the ability to calibrate, maintain and troubleshoot HART instrumentation. Integrated HART communication functions permit you to moni- tor, control and calibrate HART instrumentation. It handles fast pulsed instruments such as RTD trans- mitters and PLCs responding to pulses within 1 ms.
Pressure Enabled
753: A complete documenting calibrator
The 753 is a complete multifunction documenting calibrator and includes a PC interface that lets you load procedures, lists and instructions created with software— or unload data for printing, archiving, and analysis. The 753 can hold a full week of calibrations and procedures.
Specifications
Ordering information
HART is a registered trade mark of the HART Communications Foundation.
Fluke 753
Summary specifications: best case, mid-range, one year.
Battery life: Typically over eight hours Internal battery pack: Li ion 4400 mAh Battery replacement: Via twist lock fastener without opening calibrator; no tools required Weight: 1.2 kg (2.7 lb)
Size (HxWxD): 245 mm x 136 mm x 63 mm (9.6 in x 5.4 in x 2.5 in)
Functions
Measure
Sourcing
DC voltage
0.020 % reading + 0.005 % full scale
0.01 % output + 0.005 % full scale
DC current
0.01 % reading + 5 μA
0.01 % output + 0.003 mA
Resistance
0.05 % reading + 50 mΩ
0.01 % output + 240 mΩ
Frequency
0 to 50 KHz, ± 0.5 Hz to 1100 Hz
0 to 50 KHz, ± 0.1 Hz to 1099.9 Hz
Thermocouples
0.3 °C
0.2 °C
RTDs
0.3 °C
0.1 °C
Pressure
To 0.025 % of full scale, per pressure module specifications
Included accessories
Models
Three sets of stackable test leads, three sets of test probes with three sets of “extended tooth” alligator clips, two sets of hook clips, li-ion battery pack, battery charger, field soft case, USB communication cable, getting started guide, instruction manual on CD, traceable certificate of calibration, DPC/TRACK2 sample software that enables upload and printing of calibration records. Model Fluke-754 includes HART communication cable.
FLUKE-754 Documenting Process Calibrator-HART
FLUKE-753 Documenting Process Calibrator
Software media, instruction manual, USB cable.
FLUKE-750SW DPC/TRACK2 Software
Test leads, test probes and alligator clips. Quick reference guide, traceable certificate of calibration, manual on CD. Additional hook clips (709H only) for HART communication.
FLUKE-709 Precision Current Loop Calibrator
FLUKE-709H Precision Current Loop Calibrator-HART
Special Lemo to USB cable for upload-download, software media and manual on CD.
FLUKE-709H/ Datalogging Cable and Software TRACK
For more information, go to www.fluke.com/754
Process Calibration Tools
39
Recommended software
Instrumentation management software
The Fluke 753 and 754 are compat- ible with Fluke 750SW DPC/TRACK2 software and with software from Cornerstone, Emerson, Honeywell, On Time Support, Prime Technolo- gies, Yokogowa, Intools, Meridium and Beamex.
For more information, visit
www.fluke.com/software
Fluke 709/709H Precision Current Loop Calibrators
• Best-in-class accuracy at 0.01 % reading
• HART Communication (709H only) communicate with and test HART smart instruments
• Compact rugged design
• Intuitive user interface with quick-
set knob for fast setup, easy to use
• 24 V dc loop power with mA
measure mode
• Resolution of 1 μA on mA ranges
• Built in selectable 250 Ω resistor for
HART communications
• Simple two wire connection for all
measurements
• Valve test (source
and simulate defined mA values with % keys)
• Upload logged mA measure- ments and HART device data using the 709H with optional 709H/ TRACK software
Check price and availability at
www.fluke.com/wtb
Recommended accessories
750Pxx
Pressure Modules
See page 42
700PTP-1
Pneumatic
Test Pump
See page 72
750SW
DPC/TRACK2 Software
C799
Field Soft Case
See page 67