Page 75 - Fluke Test Tools Catalog
P. 75
Fluke current clamps
For use with multimeters, portable oscilloscopes and power quality analyzers
AC only models
i200 i400
i200s i400s
AC current clamp specifications
i200 i200s i400
i800
i1000s
i1000s
i3000s
i3000s Flex/i6000s
i3000s Flex-24 (24 in dia), i3000s Flex- 36 (36 in dia), i6000s Flex-24 (24 in dia) i6000s Flex-36 (36 in dia)
i400s
i800
i3000s
i2000 Flex
i3000s Flex
i6000s
AC current range    1 A to 200 A   1 A to 200 A   1 A to 400 A   0.5 A to 400 A
1 A to 800 A    0.2 A to 1000 A   1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   60 A to 6000 A
Accuracy
< 3 % + 0.5 A 48 < 1 % + 0.5 A 2 % + 0.06 A to65Hz 48Hzto65Hz 45Hzto400Hz
.5 A to 40 A, 2% +.015A,5 A to 400 A,
2 % + .04 A, 45 to 400 Hz
0.1 A to 10 A ±3%+.01A, 10 A to 200 A ± 2 %, 200 A to 800 A
0.2 to 10 A:
3%+0.1A 10 A to 100 A: 2 % + 0.5 A 100Ato1000A:
1 to 30 A: 2%+0.1A 1 to 300 A: 2 % + 0.5 A 1 to 3000 A:
± 1 % of range 45to65Hz Ranges:
20 A, 200 A, 2000 A
30 Hz to 10 kHz 5 Hz to 100 kHz 10 Hz to 100 kHz
(typical)              (- 3 dB)
± 1 % of range, 45Hzto65Hz Ranges:
30 A, 300 A, 3000 A
± 1 % of range 45to65Hz
±1% 1%+1A 2%+2A 48 to 65 Hz 48 to 65 Hz
Bandwidth (-3 dB)    40 Hz to 40 kHz   40 Hz to 40 kHz   5 kHz to 20 kHz   5 Hz to 10 kHz
10 Hz to 20 kHz
10 Hz to 50 kHz
10 Hz to 50 kHz,
Maximum conductor diameter
Maximum
conductor size
Output levels
Output cable
Warranty    One-year   One-year   One-year    One-year
20 mm (0.8 in) 20 mm (0.8 in) 32 mm (1.25 in) 300MCM 300MCM 750MCM
32 mm (1.25 in) 750MCM
177 mm (7 in) or
610mmor915mm 610mm(24in)or
54 mm (2.13 in) 54 mm (2.13 in) 64 x 100 mm
(2.52 x 3.94 in)      265 mm (10.4 in)   289 mm (11.4 in)
177 mm (7 in)
193 mm (7.6 in) or
1 mA/A 10 mV/A 1 mA/A 100 mV/A
10 mV/A 1 mV/A
2-500MCMor 2-500MCMor 64mm 1-1000 MCM 1-1000 MCM (2.52 in)
1 mA/A 1 mV/A 10 mV/A 10 mV/A 1 mV/A
100 mV/A 0.1 mV/A 1.6 m shrouded 1.6 m to BNC 2.1 m to BNC banana plugs termination termination
610mm
(24 in) circumference 100 mV/A
10 mV/A
1 mV/A
2 m with double shrouded banana plugs
circumference
100 mV/A 10 mV/A
1 mV/A 2.1 m to BNC termination
915mm (36 in)
50 mV/A
5 mV/A
0.5 mV/A
2 m to BNC,
4 mm plug adapter supplied
1.5 m shrouded 2 m to BNC 1.5 m shrouded banana plugs termination banana plugs
2.5 m to BNC termination
Safety rating    CAT III 600 V   CAT III 600 V   CAT III 1000 V
CAT IV 600 V    CAT IV 600 V
One-year    One-year   One-year   One-year   One-year   One-year CAT III 600 V    CAT III 600 V   CAT III 600 V   CAT III 600 V   CAT III 600 V   CAT III 600 V
CAT III 1000 V
AC current clamp selection guide
Meter
114/116
i200
i200s
1 A to 200 A
i400
i400s
0.6 A to 400 A*
i800 i1000s i3000s
0.6 A to 1000 A* 1 A to 3000 A 60 A to 800 A 0.6 A to 1000 A* 1 A to 3000 A 60 A to 800 A 0.6 A to 1000 A* 1 A to 3000 A
i2000 Flex1
2 A to 2000 A 2 A to 2000 A 2 A to 2000 A
i3000s Flex
3 A to 3000 A 3 A to 3000 A 3 A to 3000 A
i6000s
Best to use i430Flex-TF Best to use i430Flex-TF Best to use i430Flex-TF
115/117    60 A to 200 A   1 A to 200 A   60 A to 400 A   0.6 A to 400 A* 233    60 A to 200 A   1 A to 200 A   60 A to 400 A   0.6 A to 400 A*
27II    2 A to 200 A   1 A to 200 A   2 A to 400 A   1 A to 400 A* 28II    1.8 A to 200 A   1 A to 200 A   1.8 A to 400 A   1.8 A to 400 A 77 IV      1 A to 200 A     1 A to 400 A* 175/177/179    3 A to 200 A   1 A to 200 A   3 A to 400 A   1 A to 400 A*
2 A to 800 A    0.1 A to 1000 A*   1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF 1.8 A to 800 A    0.2 A to 1000 A*   2 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF
0.1 A to 1000 A*    1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF 3 A to 800 A    0.3 A to 1000 A*   3 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF
1577/1587
Insulation Meter
83V/88V    2 A to 200 A   1 A to 200 A   2 A to 400 A   1 A to 400 A*
87V    2 A to 200 A   1 A to 200 A   2 A to 400 A   2 A to 400 A* 287/289    1 A to 200 A   1 A to 200 A   1 A to 400 A   0.5 A to 400 A*
3 A to 400 A 0.3 A to 1000 A* 3 A to 3000 A
2 A to 2000 A
3 A to 3000 A
Best to use
3 A to 200 A
1 A to 200 A
3 A to 400 A
3 A to 400 A*
i430Flex-TF 2 A to 800 A    0.1 A to 1000 A*   1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF 2 A to 800 A    0.2 A to 1000 A*   2 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use
43B Power Quality Analyzer
434/435 Power Quality Analyzer 120 Series ScopeMeters
1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A
0.35 A to 400 A 1.2 A to 400 A 2.5 A to 400 A 1 A to 400 A
i430Flex-TF 1 A to 800 A    0.2 A to 1000 A*   1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF Best to use
0.1 A to 1000 A 1 A to 3000 A 0.3 A to 1000 A 1.2 A to 3000 A 0.25 A to 1000 A 2.5 A to 3000 A
0.1 A to 1000 A 1 A to 3000 A
2 A to 2000 A
3 A to 3000 A
i430Flex-TF
Best to use i430Flex-TF Best to use i430Flex-TF
190 Series
ScopeMeters
8808A    1 A to 200 A   1 A to 200 A   1 A to 400 A   0.5 A to 400 A*
2 A to 2000 A
2 A to 2000 A
Best to use 3 A to 3000 A 3 A to 3000 A
Best to use
i430Flex    i430Flex-TF
8845A/8846A    1 A to 200 A   1 A to 200 A   1 A to 400 A   1 A to 400 A*
1 A to 800 A    0.1 A to 1000 A*   1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF 1 A to 800 A    0.2 A to 1000 A*   1 A to 3000 A   2 A to 2000 A   3 A to 3000 A   Best to use i430Flex-TF
787/789 Process Meters
50 A to 200 A
1 A to 200 A
50 A to 400 A
2 A to 400 A*
50 A to 440 A 0.2 A to 1000 A* 2 A to 3000 A
2 A to 2000 A
3 A to 3000 A
Best to use i430Flex-TF
* Requires PM9081/001 Adapters.
1 Three range version.
2 Current and watt readings will be multiples of 10 higher or lower than actual on some ranges.
For more information, go to www.fluke.com/accessories
Accessories 73