Page 18 - 810 Trianing Book Extract
P. 18
Quick and easy steps to review the diagnostic report
5
Export report to PDF
Once you decide that a fault requires review, select the Export to PDF button from the View Diagnosis screen.
Use the PDF report as a inal review of the results: conirm the data is valid, review the results, and then send the
PDF report via email to the managers and planners to make up a work order to repair the machine.
STEP
Review the summary (front page of the report)
Were the correct locations measured?
Any missing?
Is the maximum peak good?
Other factors?
Is the machine speed good?
Wrong speed?
Is the overall vibration good?
Other factors?
Is the diagnosis good?
Fault, severity, recommendation?
For more detailed information: see page 105
and 106.
STEP
Check the machine setup (last page of the report)
Does the machine speed match nameplate speed?
If VFD is Yes, was VFD level checked and new
speed entered?
Does 1X RPM on the report match the setup speed?
Is the machine speed good? Wrong speed?
Is the machine setup correct? Is anything
missing?
If you ind the setup is wrong or missing informa-
tion, then ix the setup and measure again.
For more detailed information: see page 112
and 113.
Quick reference guide
Mark this page as a Quick Guide to review PDF
reports
Chapter 5: Step-by-step: diagnose and review the results 119